韶关发电厂10号炉发生了2起高温过热器爆管,其原因是超温爆管。经检查,发现管内有1个直径比管子内径稍小、厚度约5mm、可在管内转动的圆柱形金属堵头,卡在联箱短管安装焊缝上面,致使高温过热器管内流通蒸汽量减少,管壁冷却不足,长期超温运行,最终发生过热爆管。堵头来历是制造时掉入,又未能取出,安装时也未能发现、取出,最终导致锅炉高温过热器爆管。
Shaoguan Power Plant 10 furnace occurred 2 high-temperature superheater tube burst, the reason is over-temperature burst tube. After examination, it was found that the pipe had a cylindrical metal plug with a diameter slightly smaller than the inner diameter of the pipe and a thickness of about 5 mm. The cylindrical metal plug was rotated in the pipe and stuck on the weld of the header pipe, causing the amount of steam flowing through the pipe of the high-temperature superheater to be reduced , Inadequate wall cooling, long-term over-temperature operation, the final superheat tube burst. Plug origin is falling into the manufacturing, but also failed to remove, also failed to find the installation, remove, eventually leading to boiler high temperature superheater tube burst.