Objective: To investigate the feasibility of chemosensitivity testing of antitumor drugs by flow cytometry in clinical applications so as to provide experimental and theoretical basis for the establishment of a novel antitumor drugs sensitivity testing and the screening of particular antitumor drugs. Methods: Detect the apoptosis rate of 12 cases of Molt-4 cell line, 57 cases of fresh clinical gastrointestinal tumor cells by Sub-G1 and Annexin V assay of flow cytometry under the effects of antitumor drugs at different times and the outcomes were compared with the ones of the MTT (3-(4,5-dimethylthiazolyl-2) -2,5-diphenyltetrazolium bromide) assay. Results: The lethality of drugs on Molt-4 cell, clinical gastrointestinal tumor cells had a positive correlation with the acting time of antidrugs by employing Annexin V, Sub-G1 and MTT assay. Drug-incurring maximum lethality of Annexin V assay was higher than MTT colorimetric assay, that of Sub-G1 was lower than MTT assay, the virtual times of Annexin V and Sub-G1 assay were obviously earlier than that of MTT colorimetric assay. Conclusion: Annexin V and Sub-G1 assay of flow cytometry can be taken as potent protocols testing anti-tumor drug chemosensitivity. Annexin V assay is featured by more sensitive, concise, reliable compared with the classical chemosensitivity testing assay of MTT colorimetric assay and it possesses clinical applied value.
Objective: To investigate the feasibility of chemosensitivity testing of antitumor drugs by flow cytometry in clinical applications so as to provide experimental and theoretical basis for the establishment of a novel antitumor drugs sensitivity testing and the screening of particular antitumor drugs. Methods: Detect the apoptosis rate of 12 cases of Molt-4 cell line, 57 cases of fresh clinical gastrointestinal tumor cells by Sub-G1 and Annexin V assay of flow cytometry under the effects of antitumor drugs at different times and the events were compared with the ones of the MTT ( Results: The lethality of drugs on Molt-4 cell, clinical gastrointestinal tumor cells had a positive correlation with the acting time of antidrugs by employing Annexin V, Sub-G1 and MTT assay. Drug-incurring maximum lethality of Annexin V assay was higher than MTT colorimetric assay, that of Sub-G1 was lower than MTT assay, the virtual times of Annexin V and Sub-G1 assay were clear earlier than that of MTT colorimetric assay. Conclusion: Annexin V and Sub-G1 assay of flow cytometry can be taken as potent protocols testing anti-tumor drug chemosensitivity. Annexin V assay is featured by more sensitive, concise, reliable compared with the classical chemosensitivity testing assay of MTT colorimetric assay and it possesses clinical applied value.