论文部分内容阅读
【摘要】目的:探讨微柱凝胶技术在ABO新生儿溶血病中的应用。方法:采用微柱凝胶技术对66例ABO新生儿溶血病的血样进行检测,同时以传统的试管法抗球蛋白试验作比较。结果:两种方法在ABO-HDN的检出率上无统计学差异,但微柱凝胶技术可以检出试管法所不能检出的阴性血样。结论:微柱凝胶技术能快速准确的检出ABO新生儿溶血病,是直观可靠的方法。
【关键词】微柱凝胶技术;ABO新生儿溶血病
Application of Gel Coombs'test technique in testing ABO-HDN
Jiang Jianfeng (The first people's hospital in hefei Anhui 230061, China)
Miao Yanxia (The branch of first People's hospital shushan hefei Anhui 230061,China)
【Abstract】Objective:To approach the application of Gel Coombs'test technique in testing ABO-HDN. Methods:66 newborns with ABO-HDN were tested by Gel Coombs'test technique comparing with traditional TAT(Tube Agglutination Technique)anti human IgG test.Results:In statistic, testing rate of two methods in ABO-HDN was not obviously different,but Gel Coombs'test technique could test the negative blood samples that could not be tested by TAT.Conclusions:Gel Coombs'test technique can test ABO-HDN quickly and exactly, the technique was reliable and directly observed.
【Key words】Gel Coombs'test technique;ABO-HDN(ABO-Hemolytic Disease of Newborn)
新生儿溶血病(hemolytic disease 0f the new born,HDN)是由于母亲体内与新生儿红细胞抗原不配合的IgG性质的血型抗体进入新生儿体内引起的同种被动免疫性疾病[1]。其中以ABO新生儿溶血病较为常见。直接抗球蛋白试验、释放试验、游离抗体实验被称为新生儿溶血病诊断的“三项试验”。诊断ABO-HDN的最有力证据是证实患儿红细胞被来自母亲的IgG抗A(B)抗体所致敏[2]。传统的试管法抗人球蛋白实验(Coombs试验)检测血清IgG抗体,结果可靠,但操作步骤繁琐、耗时。我院近年来引进了微柱凝胶技术,并应用于ABO新生儿溶血病的检测中,取得了很
好的效果。现介绍如下:
1材料与方法
1.1仪器:37℃孵育器、专用离心机、新生儿溶血病卡Ⅰ(A、B 、AB、D、 ctrl、 AHG)新生儿溶血病卡Ⅱ(抗人球蛋白卡,6孔)均由长春博迅生物技术有限责任公司提供。
1.2试剂:抗人球蛋白试剂、ABO试剂红细胞、2-巯基乙醇等由上海输血技术公司提供。
1.3检测样本:我院66例ABO-HDN患儿的血液标本。
1.4实验方法
1.4.1 血型鉴定及直接抗人球蛋白试验取新生儿溶血病卡Ⅰ一张,每孔加入0.5%患儿红细胞悬液50ul,立即使用专用离心机离心5分钟,900rpm2分钟,1500rpm3分钟。取出,判定结果。
1.4.2 游离放散试验取新生儿溶血病卡Ⅱ一张,前三孔标明游离Ac、Bc、Oc,后三孔标明放散Ac、Bc、Oc,前三孔加入患儿血清50μl,后三孔加入患儿红细胞热放散液各50μl(患儿热放散液制作方法:取三洗后患儿压积红细胞1ml,加入等量或半量6%牛血清白蛋白混匀,置56℃水浴箱中孵育10min,期间不断摇动,取出后置56℃热套管中,立即2000rpm离心2~3分钟,取上清液即热放散液),分别加入相应0.5%试剂ABO红细胞50μl,将新生儿溶血病卡Ⅱ置专用37℃孵育器中孵育15min,立即使用专用离心机离心5 分钟,900rpm2分钟,1500rpm3分钟。取出,根据新生儿血型判读结果。
1.4.3 试管法抗球蛋白试验采用传统的试管法对66例患儿标本同时做抗球蛋白试验。
1.4.4 结果判读在ABO-HDN血清学试验中,直抗试验是检查新生儿红细胞是否被IgG抗体致敏,血清游离抗体和放散液抗体测定是检查IgG抗体的存在和类型[3]。直抗、游离抗体、放散液抗体三项试验中,有2~3项阳性时,可以确认为HDN;如有一项阳性,只有放散液抗体阳性可以确认为HDN[4] 。
2结果分析
2.166例ABO-HDN血样微柱凝胶技术和试管法检测阳性结果

两种方法比较,直抗阳性率差异无显著性(x2=0.298,P>0.05),游离抗体阳性率差异无显著性(x2=1.111,P>0.05),放散试验阳性率差异无显著性(x2=1.550,P>0.05)。
2.2试管法直抗试验、游离试验及放散试验阳性血样,微柱凝集试验全部检测为阳性。微柱凝集试验同时检出3例试管法直抗试验阴性,5例试管法游离试验阴性,5例试管法放散试验阴性血样。
3讨论
HDN主要原因是母体经免疫产生同种免疫抗体IgG通过胎盘进入胎儿血循环,与胎儿红细胞结合引起免疫反应性溶血[5]。新生儿溶血病的主要症状和体征有水肿、黄疸、贫血和肝脾肿大,高黄疸者可能导致核黄疸。症状轻重一般取决于母亲的抗体强度、亚类、胎儿红细胞抗原发育程度、胎儿代偿性造血的能力以及免疫功能等诸因素[2]。
抗球蛋白试验是检测HDN的经典方法,能较敏感的检出红细胞膜上的不完全抗体和补体。传统的抗球蛋白试管法易产生假阴性,操作步骤多,重复性差,需高水平技师操作[6]。微柱凝胶管内填充有葡聚糖凝胶和抗人球蛋白试剂,其反应原理是建立在抗球蛋白试验基础上的,是红细胞抗原和抗体在凝胶介质中发生凝集反应。从本次试验结果可以看出,虽然两种方法在ABO-HDN的检出率上无统计学差异,但微柱凝胶技术可以检出试管法所不能检出的阴性血样。并且结果清晰明了,稳定可靠,方法简单,无需洗涤,试验时间短,可大大提高ABO-HDN的阳性检出率,有利于ABO-HDN的早期诊断和治疗[7],是一项值得推广的技术。
参考文献
[1]李勇.人类红细胞血型学实用理论与实验技术[M] .北京:中国科学技术出版社,1999,173-175.
[2]刘达庄.免疫血液学[M].上海:上海科学技术出版社,2002,132-135.
[3]刘毅,刘衍春,刘洪莉等.微柱凝胶技术在新生儿溶血病血清学检查中的运用.临床检验杂志.2005,23(1):43.
[4]王培华.输血技术学[M].北京:人民卫生出版社,1998,210.
[5]杨于嘉.新生儿溶血病[J].医学临床研究.2002,19(7):513.
[6]叶有玩,胡劲辉,范世珍等.微柱凝集技术检测新生儿溶血病的临床应用.中国实验诊断学.2004,8(3):297.
[7]温施秋,张英.微柱凝胶试验在新生儿溶血病检测中的应用.现代医学检验杂志.2003,18(3):35.
【关键词】微柱凝胶技术;ABO新生儿溶血病
Application of Gel Coombs'test technique in testing ABO-HDN
Jiang Jianfeng (The first people's hospital in hefei Anhui 230061, China)
Miao Yanxia (The branch of first People's hospital shushan hefei Anhui 230061,China)
【Abstract】Objective:To approach the application of Gel Coombs'test technique in testing ABO-HDN. Methods:66 newborns with ABO-HDN were tested by Gel Coombs'test technique comparing with traditional TAT(Tube Agglutination Technique)anti human IgG test.Results:In statistic, testing rate of two methods in ABO-HDN was not obviously different,but Gel Coombs'test technique could test the negative blood samples that could not be tested by TAT.Conclusions:Gel Coombs'test technique can test ABO-HDN quickly and exactly, the technique was reliable and directly observed.
【Key words】Gel Coombs'test technique;ABO-HDN(ABO-Hemolytic Disease of Newborn)
新生儿溶血病(hemolytic disease 0f the new born,HDN)是由于母亲体内与新生儿红细胞抗原不配合的IgG性质的血型抗体进入新生儿体内引起的同种被动免疫性疾病[1]。其中以ABO新生儿溶血病较为常见。直接抗球蛋白试验、释放试验、游离抗体实验被称为新生儿溶血病诊断的“三项试验”。诊断ABO-HDN的最有力证据是证实患儿红细胞被来自母亲的IgG抗A(B)抗体所致敏[2]。传统的试管法抗人球蛋白实验(Coombs试验)检测血清IgG抗体,结果可靠,但操作步骤繁琐、耗时。我院近年来引进了微柱凝胶技术,并应用于ABO新生儿溶血病的检测中,取得了很
好的效果。现介绍如下:
1材料与方法
1.1仪器:37℃孵育器、专用离心机、新生儿溶血病卡Ⅰ(A、B 、AB、D、 ctrl、 AHG)新生儿溶血病卡Ⅱ(抗人球蛋白卡,6孔)均由长春博迅生物技术有限责任公司提供。
1.2试剂:抗人球蛋白试剂、ABO试剂红细胞、2-巯基乙醇等由上海输血技术公司提供。
1.3检测样本:我院66例ABO-HDN患儿的血液标本。
1.4实验方法
1.4.1 血型鉴定及直接抗人球蛋白试验取新生儿溶血病卡Ⅰ一张,每孔加入0.5%患儿红细胞悬液50ul,立即使用专用离心机离心5分钟,900rpm2分钟,1500rpm3分钟。取出,判定结果。
1.4.2 游离放散试验取新生儿溶血病卡Ⅱ一张,前三孔标明游离Ac、Bc、Oc,后三孔标明放散Ac、Bc、Oc,前三孔加入患儿血清50μl,后三孔加入患儿红细胞热放散液各50μl(患儿热放散液制作方法:取三洗后患儿压积红细胞1ml,加入等量或半量6%牛血清白蛋白混匀,置56℃水浴箱中孵育10min,期间不断摇动,取出后置56℃热套管中,立即2000rpm离心2~3分钟,取上清液即热放散液),分别加入相应0.5%试剂ABO红细胞50μl,将新生儿溶血病卡Ⅱ置专用37℃孵育器中孵育15min,立即使用专用离心机离心5 分钟,900rpm2分钟,1500rpm3分钟。取出,根据新生儿血型判读结果。
1.4.3 试管法抗球蛋白试验采用传统的试管法对66例患儿标本同时做抗球蛋白试验。
1.4.4 结果判读在ABO-HDN血清学试验中,直抗试验是检查新生儿红细胞是否被IgG抗体致敏,血清游离抗体和放散液抗体测定是检查IgG抗体的存在和类型[3]。直抗、游离抗体、放散液抗体三项试验中,有2~3项阳性时,可以确认为HDN;如有一项阳性,只有放散液抗体阳性可以确认为HDN[4] 。
2结果分析
2.166例ABO-HDN血样微柱凝胶技术和试管法检测阳性结果

两种方法比较,直抗阳性率差异无显著性(x2=0.298,P>0.05),游离抗体阳性率差异无显著性(x2=1.111,P>0.05),放散试验阳性率差异无显著性(x2=1.550,P>0.05)。
2.2试管法直抗试验、游离试验及放散试验阳性血样,微柱凝集试验全部检测为阳性。微柱凝集试验同时检出3例试管法直抗试验阴性,5例试管法游离试验阴性,5例试管法放散试验阴性血样。
3讨论
HDN主要原因是母体经免疫产生同种免疫抗体IgG通过胎盘进入胎儿血循环,与胎儿红细胞结合引起免疫反应性溶血[5]。新生儿溶血病的主要症状和体征有水肿、黄疸、贫血和肝脾肿大,高黄疸者可能导致核黄疸。症状轻重一般取决于母亲的抗体强度、亚类、胎儿红细胞抗原发育程度、胎儿代偿性造血的能力以及免疫功能等诸因素[2]。
抗球蛋白试验是检测HDN的经典方法,能较敏感的检出红细胞膜上的不完全抗体和补体。传统的抗球蛋白试管法易产生假阴性,操作步骤多,重复性差,需高水平技师操作[6]。微柱凝胶管内填充有葡聚糖凝胶和抗人球蛋白试剂,其反应原理是建立在抗球蛋白试验基础上的,是红细胞抗原和抗体在凝胶介质中发生凝集反应。从本次试验结果可以看出,虽然两种方法在ABO-HDN的检出率上无统计学差异,但微柱凝胶技术可以检出试管法所不能检出的阴性血样。并且结果清晰明了,稳定可靠,方法简单,无需洗涤,试验时间短,可大大提高ABO-HDN的阳性检出率,有利于ABO-HDN的早期诊断和治疗[7],是一项值得推广的技术。
参考文献
[1]李勇.人类红细胞血型学实用理论与实验技术[M] .北京:中国科学技术出版社,1999,173-175.
[2]刘达庄.免疫血液学[M].上海:上海科学技术出版社,2002,132-135.
[3]刘毅,刘衍春,刘洪莉等.微柱凝胶技术在新生儿溶血病血清学检查中的运用.临床检验杂志.2005,23(1):43.
[4]王培华.输血技术学[M].北京:人民卫生出版社,1998,210.
[5]杨于嘉.新生儿溶血病[J].医学临床研究.2002,19(7):513.
[6]叶有玩,胡劲辉,范世珍等.微柱凝集技术检测新生儿溶血病的临床应用.中国实验诊断学.2004,8(3):297.
[7]温施秋,张英.微柱凝胶试验在新生儿溶血病检测中的应用.现代医学检验杂志.2003,18(3):35.