二维超声心动图(2DE)心尖两切面与双面左室造影(LVG)对比研究一致显示:定量测定室壁节段运动(RWM),选择固定轴系统定量检出RWM异常(RWMA)病例具有和浮动轴系统相同的特异性、敏感性和准确性(P均>0.05)。然而,对心肌梗塞(MI)患者的正常和异常节段定位固定轴较浮动轴更准确;固定轴所测节段EF值能将不同程度RWMA定量区分开,能反映出矛盾运动,而浮动轴则掩盖了这些矛盾运动。提示固定轴系统优于浮动轴系统。
A two-dimensional echocardiographic (2DE) comparison of apical two-sided and double-sided left ventricular imaging (LVG) consistently showed that RWM was quantified and the RWMA was quantified using a fixed-axis system The same specificity, sensitivity and accuracy as the floating axis system (P> 0.05). However, the normal and anomalous segments of the fixed-axis positioning axis in MI patients are more accurate than the floating axis; the EF values measured on the fixed axis segment can distinguish RWMA quantitatively to reflect conflicting movements and the floating axis Then cover up these contradictory movements. Tips Fixed shaft systems outperform floating shaft systems.