针对300MW、600MW大容量四角切圆燃烧锅炉水平烟道内烟温偏差的现状,用数值分析的手段对炉内和水平烟道内流场进行了计算,得出炉膛出口残余旋转造成了炉内左右侧烟气流动图谱不同,从而进一步引发水平烟道内烟温偏差的结论,并根据数值计算得到的炉内和水平烟道内流动特性,指出检验人员在现场进行锅炉内部检验时应注意的环节。
Aiming at the present situation of smoke temperature deviation in horizontal flue of 300MW and 600MW large-capacity tangential fired boilers, the numerical analysis is used to calculate the flow field in the flue and the horizontal flue. The results show that the residual rotation at the outlet of the furnace caused the left and right sides of the furnace The results of flue gas temperature fluctuation in horizontal flue are further induced. According to the numerical calculation, the flow characteristics in the flue and the horizontal flue are pointed out, and the points that inspectors should pay attention to in the field of boiler internal inspection are pointed out.