【摘 要】
:
Purpose:The efficacy of spatially fractionated(GRID)radiotherapy for treating bulky tumors has been recognized and demonstrated.GRID therapy might improve tumor control while reducing normal tissue to
【机 构】
:
Graduate School of Medicine,Kinki University,Department of Radiation Oncology,377-2 Ohno-higashi,Osa
【出 处】
:
The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015
论文部分内容阅读
Purpose:The efficacy of spatially fractionated(GRID)radiotherapy for treating bulky tumors has been recognized and demonstrated.GRID therapy might improve tumor control while reducing normal tissue toxicity.In this study,we evaluated the dosimetric characteristics of delivering GRID therapy using a multi-leaf collimator(MLC)with the Vero4DRT.Method:Four grid patterns were prepared with an(a)isolated or(b)adjacent pattern,and grid opening measuring 10×10 mm2 or 5×5 mm2 on the plane 100 cm from the source.These were referred to as GRID10a,GRID10b,GRID5a,and GRID5b.We used 6 MV xrays and irradiated EBT3 film to measure the valley-to-peak dose ratio(V-P ratio)which was defined as dose ratio in the blocked and opened areas at three depths(1.5,5,and 10 cm),with an actual irradiation size at 1.5 cm depth,using a water-equivalent phantom.Result:The respective V-P ratios with GRID10a,GRID10b,GRID5a,and GRID5b were about 6,13.5,15.4,and 35.6%at a depth of 1.5 cm,8.4,18.1,18.7,and 39.5%at 5 cm,and 10.8,22.7,21.7,and 44%at 10 cm.The actual irradiation sizes with the four patterns were 1.0,1.0,0.6,and 0.7 cm at inline and 1.2,1.2,0.6 and 0.7 cm at crossline,respectively.Conclusion:The Vero4DRT has features of low MLC transmission and shape penumbra and may enable the delivery of ablative doses for MLC-based GRID therapy.
其他文献
Purpose:To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy(VMAT),high-dose-rate(HDR)brachytherapy,and low-dose-rate(LDR)permanent seeds implant for lo
Purpose:To improve the set up accuracy of patient alignment,we developed a new real time patient alignment monitoring system based on laser sensing technology and evaluated its feasibility.Methods:The
Introduction:Radiotherapy is a standard treatment of breast cancer after complete surgery.The curved surface of the breast and the geometry that is laid near the critical organs,treatment techniques f
Objective:To select reasonable treatment methods for liver tumor,the dose distribution by three-dimensional treatment planning system(TPS)for target area and normal liver around liver tumor in four in
Purpose:To compare dosimetry difference in the whole central nervous system(CNS)radiotherapy in both intensity-modulated radiation therapy(IMRT)and three dimensional conformal radiation therapy(3D-CRT
Objective:To study the effects of whole carbon fiber couch and virtual couch of VARIAN Linear Accelerator on radiotherapy dose of high energy X-ray.Methods:The solid water phantom was fixed at the cen
Radiation therapy was recognized as a potential cause of cancer many years ago.Patients undergoing radiation therapy may have an increased risk of second malignancies as a result of radiation away fro
Objective To evaluate CBCT image quality and its long-term stability for HUs in different scanning conditions.Materials and Methods With the OBI of Varian iX system,Catphan 504 phantom in the differen
To estimate the α/β ratio of late rectal toxicity in case of prostate cancer radiotherapy; and to investigate whether correcting the rectal dose-volume histogram(DVH)for differences in dose per fracti
Objective To compare the dosimetric difference between anisotropic analytical algorithm(AAA)and pencil beam convolution(PBC)for intensity modulated radiation therapy(IMRT)Plans in esophageal carcioma.