Dosimetric study on treatment planning of the whole central nervous system(CNS)by different radiothe

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:luckkycaroll
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:To compare dosimetry difference in the whole central nervous system(CNS)radiotherapy in both intensity-modulated radiation therapy(IMRT)and three dimensional conformal radiation therapy(3D-CRT).Methods:In allusion to 38 patients with the whole CNS radiotherapy,IMRT and 3D-CRT plans were separately designed.Under the precondition of guaranteeing two plans all meet the clinical requirements,to compare target dose distribution,conformal index(CI)and homogeneity index(HI),exposure doses of both organs at risk(OARs)and normal tissues outside of target,monitor units(MU)and treatment time,respectively,and to investigate the dosimetry difference.Results:Compared with 3D-CRT plan,V5 and average dose Dmean of lung for IMRT plan increased markedly,and the difference was statistically significant(P < 0.05),whereas V20 was rather lower(P < 0.05),V10 change was not obvious(P>0.05); radiation dose,V10 and V20 of heart significantly decreased(P < 0.05)while radiation dose and volume of kidney remarkably increased(P < 0.05); V5 and D50 of liver were relatively higher(P < 0.05),moreover,V15 and V20 decreased notably(P < 0.05),but V10 change was not obvious(P>0.05); maximum dose of crystalline lens had no statistical difference(P>0.05); eye maximum dose was prominently lower(P < 0.05).Conclusions:IMRT plan is more capable of distinctly improving the dosimetric index of target and immensely reducing the high dose radiation volume of normal tissues and OARs than 3D-CRT plan,furthermore,IMRT plan can better enhance HI(P=0.67)and CI(P=0.00)of the target dose distribution,also,ameliorate problems of both dose distribution inhomogeneity and dose "hot" or "cold" spots existed in 3D-CRT plan.High dose volume above 50%prescription dose of normal tissues significantly decreases in IMRT plan,the dosimetric indices of OARs are mixed,although both plans can meet the clinical requirements,IMRT plan has an advantage over 3D-CRT plan in clinical dosimetry.
其他文献
Purpose:Pencil beam dose calculation algorithm(PBDCA),due to its efficiency and robustness,has been widely used in most commercial treatment planning systems(TPS).The purpose of this study is to devel
Objective:To study acute radiation-induced small bowel damage in patients with abdominal-and-pelvic tumor radiation therapy,in order to explore the clinical and dosimetric factors associated with grad
Objective The paper is to perfect complete the QA process by developing of the method used to fast verify the center position of body patient which are treated with Cynthia Gamma Knife.method The rese
Purpose:Radiation therapy oncology group(RTOG) 0631 suggest different planning method in spine stereotactic body radiation therapy(SBRT) according to location of cancer owing to its distinct shape.The
会议
Purpose The difference between three-dimensional(3D)and four-dimensional(4D)dose is effected by factors such as tumor size and motion amplitude.To propose quantitative results about the effect by thes
Purpose:Radiotherapy has been increasingly adopted in clinical practice for tumor treatment.FDS Team has been focused on the key physical and technical issues of accurate radiotherapy for many years.A
Purpose:To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy(VMAT),high-dose-rate(HDR)brachytherapy,and low-dose-rate(LDR)permanent seeds implant for lo
Purpose:To improve the set up accuracy of patient alignment,we developed a new real time patient alignment monitoring system based on laser sensing technology and evaluated its feasibility.Methods:The
会议
Introduction:Radiotherapy is a standard treatment of breast cancer after complete surgery.The curved surface of the breast and the geometry that is laid near the critical organs,treatment techniques f
Objective:To select reasonable treatment methods for liver tumor,the dose distribution by three-dimensional treatment planning system(TPS)for target area and normal liver around liver tumor in four in