Objective To compare the dosimetric difference between anisotropic analytical algorithm(AAA)and pencil beam convolution(PBC)for intensity modulated radiation therapy(IMRT)Plans in esophageal carcioma.
【机 构】
:
Department of Oncology,The People's Hospital of Subei,Yangzhou,22500
【出 处】
:
The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015
论文部分内容阅读
Objective To compare the dosimetric difference between anisotropic analytical algorithm(AAA)and pencil beam convolution(PBC)for intensity modulated radiation therapy(IMRT)Plans in esophageal carcioma.Methods For nine esophageal cancer cases,IMRT plan(five fixed-fields),which calculated with AAA and PBC,were generated by Varian Eclipse 8.6 treatment planning systerm.The COMPASS dose verification system was used to verify these plans.The difference of dose distribution to target and organs at risk(OAR)was compared.Results The gamma pass rates of GTV,PTV,lung and heart in AAA were higher than PBC(P<0.05).There were significant differences in Dmean、V100%、HI of GTV,and there were only significant differences in HI of PTV.AAA had more advantages.The two algorithm in double lung index between the difference was significant differences.But,the difference of AAA was smaller.The differences of heart`s Dmean,V30,V40 in two algorithm were similar(P>0.05).The D01 of spinal cord in planned value is higher than the measured value,the difference was 1.56±0.25%for AAA and 4.48±1.13%for PBC.Conclusion Esophageal carcioma radiotherapy using the AAA algorithm is more accurate than using the PBC algorithm.
其他文献
Purpose:Radiotherapy has been increasingly adopted in clinical practice for tumor treatment.FDS Team has been focused on the key physical and technical issues of accurate radiotherapy for many years.A
Purpose:To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy(VMAT),high-dose-rate(HDR)brachytherapy,and low-dose-rate(LDR)permanent seeds implant for lo
Purpose:To improve the set up accuracy of patient alignment,we developed a new real time patient alignment monitoring system based on laser sensing technology and evaluated its feasibility.Methods:The
Introduction:Radiotherapy is a standard treatment of breast cancer after complete surgery.The curved surface of the breast and the geometry that is laid near the critical organs,treatment techniques f
Objective:To select reasonable treatment methods for liver tumor,the dose distribution by three-dimensional treatment planning system(TPS)for target area and normal liver around liver tumor in four in
Purpose:To compare dosimetry difference in the whole central nervous system(CNS)radiotherapy in both intensity-modulated radiation therapy(IMRT)and three dimensional conformal radiation therapy(3D-CRT
Objective:To study the effects of whole carbon fiber couch and virtual couch of VARIAN Linear Accelerator on radiotherapy dose of high energy X-ray.Methods:The solid water phantom was fixed at the cen
Radiation therapy was recognized as a potential cause of cancer many years ago.Patients undergoing radiation therapy may have an increased risk of second malignancies as a result of radiation away fro
Objective To evaluate CBCT image quality and its long-term stability for HUs in different scanning conditions.Materials and Methods With the OBI of Varian iX system,Catphan 504 phantom in the differen
To estimate the α/β ratio of late rectal toxicity in case of prostate cancer radiotherapy; and to investigate whether correcting the rectal dose-volume histogram(DVH)for differences in dose per fracti