【摘 要】
:
Background, Motivation and Objective Multi-angle plane-wave imaging provides new opportunities for high frame rate vector-Doppler imaging, as well as improved low flow imaging by providing longer temp
【机 构】
:
Norwegian University of Science and Technology, Norway;St Olav's Hospital, Norway
论文部分内容阅读
Background, Motivation and Objective Multi-angle plane-wave imaging provides new opportunities for high frame rate vector-Doppler imaging, as well as improved low flow imaging by providing longer temporal ensembles and the possibility of coherent compounding. However, to achieve robust vector-Doppler estimates and a significant effect of the coherent compounding process a high number of angled plane waves is desired. This comes at the expense of aliasing in vector-Doppler (lowered PRF) and motion artifacts (SNR loss, blood velocity bias) in the compounding process (Ekroll et al., "On the accuracy of coherent compounding in Doppler imaging", Proc. IUS, 2014).
其他文献
Background, Motivation and Objective High-intensity focused ultrasound (HIFU) is a rapidly emerging non-invasive technique to selectively and locally produce thermal ablation of tumors located in vari
Background, Motivation and Objective Quantitative Ultrasound (QUS) is a promising technique for bone tissue evaluation. Highly focused transducers, used for QUS, have also a capability to be applied f
Background, Motivation and Objective Choosing an appropriate dynamic range for acquiring radio-frequency (RF) data from a high-frequency ultrasound (HFU) system is challenging because signals can vary
Background, Motivation and Objective Accurate discrimination of non-alcoholic steatohepatitis (NASH) from simple fatty liver is a critical issue in current clinical practice because NASH may progress
Background, Motivation and Objective The scattering is the fundamental phenomena used for US imaging of specific organs. In this study the method searching for best fitted statistical distribution (mo
Background, Motivation and Objective Maximum velocity (MV) estimation in a Doppler Sonogram is of clinical interest as it indicates severity of stenosis. It is also used in obstetrics to calculate Dop
Background, Motivation and Objective Contrast-based arterial flow vector distribution (FVD) has been deeply studied to underpin insight into cardiovascular disease diagnosis, particularly in arterial
Background, Motivation and Objective Two-dimensional (2D) blood velocity imaging inside the cardiac cavity with transthoracic echocardiography is of value in the evaluation of cardiac pumping function
Background, Motivation and Objective Speckle tracking enables 2D blood velocity estimation. Since speckle quickly decorrelates due to high velocity gradients, high frame rate imaging is crucial for ca
Background, Motivation and Objective For real-time ultrasonic 3-D volumetric imaging and velocity estimation a 2-D array transducer is needed. The complexity associated with fabricating 2-D matrix arr