3-D Vector Flow Estimation with Row-Column Addressed Arrays

来源 :2015两岸超声技术与医学研讨会 | 被引量 : 0次 | 上传用户:xiaoxiang0122
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background, Motivation and Objective For real-time ultrasonic 3-D volumetric imaging and velocity estimation a 2-D array transducer is needed. The complexity associated with fabricating 2-D matrix arrays with a large number of channels have led to the development of row-column (RC) addressed transducer arrays. The number of individual connections to the array is thereby reduced from N2 to 2N. So far, only the imaging properties of such arrays have been investigated. It is here demonstrated that RC arrays can also be used to estimate 3-D vector flow using the Transverse Oscillation (TO) method.
其他文献
Background, Motivation and Objective It is important to evaluate the elasticity of tissue-engineered cartilage, for evaluating its structural strength. However, in vivo evaluation of tissue-engineered
会议
Background, Motivation and Objective High-intensity focused ultrasound (HIFU) is a rapidly emerging non-invasive technique to selectively and locally produce thermal ablation of tumors located in vari
会议
Background, Motivation and Objective Quantitative Ultrasound (QUS) is a promising technique for bone tissue evaluation. Highly focused transducers, used for QUS, have also a capability to be applied f
会议
Background, Motivation and Objective Choosing an appropriate dynamic range for acquiring radio-frequency (RF) data from a high-frequency ultrasound (HFU) system is challenging because signals can vary
会议
Background, Motivation and Objective Accurate discrimination of non-alcoholic steatohepatitis (NASH) from simple fatty liver is a critical issue in current clinical practice because NASH may progress
会议
Background, Motivation and Objective The scattering is the fundamental phenomena used for US imaging of specific organs. In this study the method searching for best fitted statistical distribution (mo
会议
Background, Motivation and Objective Maximum velocity (MV) estimation in a Doppler Sonogram is of clinical interest as it indicates severity of stenosis. It is also used in obstetrics to calculate Dop
会议
Background, Motivation and Objective Contrast-based arterial flow vector distribution (FVD) has been deeply studied to underpin insight into cardiovascular disease diagnosis, particularly in arterial
会议
Background, Motivation and Objective Two-dimensional (2D) blood velocity imaging inside the cardiac cavity with transthoracic echocardiography is of value in the evaluation of cardiac pumping function
会议
Background, Motivation and Objective Speckle tracking enables 2D blood velocity estimation. Since speckle quickly decorrelates due to high velocity gradients, high frame rate imaging is crucial for ca
会议