【摘 要】
:
Methods:The records cervical cancer patients with squamous cell carcinoma(stage IB to IVA)underwent definitive radiotherapy in year 2009-2013 were retrospec
【机 构】
:
Medical Physics Master Degree Program,Department of Radiology,Chiang Mai University,Chiang Mai,Thail
【出 处】
:
The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015
论文部分内容阅读
Methods:The records cervical cancer patients with squamous cell carcinoma(stage IB to IVA)underwent definitive radiotherapy in year 2009-2013 were retrospective studied.The patients received the totally cumulative dose in EQD2 at point A ranged from 83.6 to 86.1 Gy.The total 130 patients were separated into 2 groups based on OTT recommended by ABS,OTT≤56 day(group1)and >56 day(group 2)and the relationship between the treatment outcomes was analyzed using Kaplan-meier,log-rank test,Cox regression,univariate and multivariate analysis(MVA)and Chi-square test.Results:OTT ranged 44-88 day.EQD2 ranged 83.6-86.1 Gy.The local control rate(p=0.681),disease metastasis free rate(p=0.867),Disease Free Survival(DFS)(p=0.769),cause specific survival(p=0.605)and Overall Survival(OS)(p=0.779)were not significantly different between 2 group.MVA identified tumor size(p=0.016 and p=0.014)as the prognostic factor of DFS and OS.There was no statistical significance in both acute and late complication [skin(p=0.922,N/A),subcutaneous tissue(p=0.558,p=1.000),Gastrointestinal(GI)(p=0.682,p=0.474)and Genitourinary(GU)(p=1.000,p=1.000),respectively].The cumulatively rectal dose(in EQD2)was further analyzed,<70 Gy3(group1)and ≥70 Gy3(group2),there were not significance different in acute GI and late GI complication(p=0.422 and p=0.459).Conclusion:The treatment outcome; local control,survival and complications,were not influence by OTT.Tumor size greater than 4 cm was the prognostic factor of DFS and OS.
其他文献
Purpose:Low count PET studies suffer from quantitative bias in iterative reconstruction methods such as MLEM or OSEM.This work aims at reducing PET image bi
Purpose Phase retrieval methods are used to disentangle pure phase from the phase contrast images.Thereare many phase retrieval methods available that addre
Purpose To investigate the dosimetric characteristics of TLD2000 thermoluminescent dosimeter(TLD).Methods 350 TLD2000 TLDs were screened to have the same se
Aims:To compare flattening filter free(FFF)beams of tomotherapy(TOMO)and C-arm based flattening filter free beams in volumetric modulated arc therapy(VMAT)o
Time consuming of dynamic multileaf collimator(dMLC)quality assurance(QA)is an issue for clinical radiotherapy department.Considering the time consuming pro
Purpose:Respiratory gated radiation therapy(RGRT)gives accurate results when a patient's breathing is stable and regular.Thus,the patient should be fully aw
Introduction:Cardiac T2* becomes a standard method to assess iron accumulation in myocardium.The reliability of T2* during the course of a longitudinal stud
Purpose:Sparse-view computed tomography(CT)reconstruction without significantly degrading image quality is an important issue in medical imaging domain.Non-
Purpose :The purpose of this study is to compare dosimetric differences during radiation treatment in patient with breast cancer between prone position vers