【摘 要】
:
Left ventricular (LV) torsion is a measurement derived from the twisting or wringing motion of the heart around its long axis.Torsion is the base-to-apex gradient in the rotation angle along the longi
【机 构】
:
Echocardiography Laboratory Gachon University South Korea
【出 处】
:
BITs 2rd Annual World Cancer Congress of Cardiology-2010(201
论文部分内容阅读
Left ventricular (LV) torsion is a measurement derived from the twisting or wringing motion of the heart around its long axis.Torsion is the base-to-apex gradient in the rotation angle along the longitudinal axis of the LV, expressed in degrees per centimeter or radians per meter.The absolute apex-to-base difference in LV rotation is stated as the net LV twist angle or the net LV torsion angle.This unique "wringing" movement of the ventricle is possible due to the helical orientation of myocardial fibers.In detail, the subendocardial fibers are arranged in a right-handed helix and the subepicardial fibers in a left-handed helix.
其他文献
The delivery of photosensitizers (PS) for the photodynamic therapy (PDT) of cancer may benefit from the proper choice of a carrier system that allows controlled release of the PS at the target tissue
Because of their highly cytotoxic nature, reactive oxygen species (ROS), e.g.H2O2, may exert remarkable antitumor potential if they can be selectively delivered into tumors.We thus developed an oxystr
The incidence of clinically significant cardiac disease during pregnancy ranges from 0.1%-4.0%.Heart disease is the most common non-obstetric cause of maternal death, and accounts for 11% of pregnancy
Fluid overloading with edema formation is a regular finding following on-pump cardiac surgery and may contribute to postoperative organ dysfunction.Hemodilution, inflammation as well as hypothemiaper
In the past two years new "ultrafast" camera systems applying multi stationery cameras and CZT crystal technology have been developed to replace the conventional Nal crystal rotating gamma camera syst
Objectives: The purpose of this study was to determine cardiac rehabilitation (CR) referral following percutaneous coronary intervention (PCI) compared to the National average, and identify barriers f
Sudden cardiac death (SCD) claims the lives of more than 400 000 persons each year in the United States.1 The implantable cardioverter defibrillator has been shown in randomized, controlled trials to
Non invasive imaging has always had a pivotal rote in cardiology.The first cardiac MRI (CMR) assessments were performed in the 1980s, when the technique was time consuming and of limited use.Recent de
Cardiovascular MR imaging (CMR) is offering diagnostic tools for a wide range of cardiovascular diseases, Although fast paced technological advances facilitated the development novel clinical applicat
320-slice CT can acquire images of the whole heart with only a single scan because of its wide coverage (0.5 mm x 320-slice =16 cm) to the through plane.Therefore, 320-slice CT makes it possible to sc