Verification of Ir-192 source position and dwell time during the high dose rate brachytherapy treatm

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:cmz
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose: The accuracy of Ir-192 source positions and dwell times has a direct impact on the safe delivery of HDR brachytherapy treatment.Verification of actual dose delivery to the target volume and normal tissue requires information on the actual source movement during the treatment.We studied a dual-pinhole imaging system for independent in vivo monitoring and dose verification of HDR brachytherapy treatment.Methods: The system consists of a plate of terbium-doped gadolinium oxysulfide(Gd2O2S:Tb)scintillator and a CCD camera capable of capturing scintillator emission images at 17 frames per second.A dual-pinhole collimator made of lead plate was used to provide three-dimensional information about the source positions.The dwell time was measured by counting the number of scintillation emission images.A 341.9 GBq Ir-192 source was placed in a water phantom at a depth of 10 cm to simulate clinical conditions.The images of the source were acquired with a source-to-scintillator distance of 20 cm.The source positions and dwell times measured with the imaging system were compared to the predefined positions and times.Results: Images of the source at a series of eight sequential dwell positions separated by a step size of 10 mm with a dwell time of 10 s could be clearly identified and discerned on the scintillator.The differences between the measured and predefined dwell positions and measurements of the dwell time were 1.4±0.2 mm and-0.6±0.3 s,respectively.Conclusions: We demonstrated that a dual-pinhole imaging system can provide clear scintillation images for verification of dwell positions and dwell times of the HDR-source.The imaging system has a potential to track the in vivo Ir-192 source in real time and to be a useful tool for quality assurance in HDR brachytherapy under clinical use.
其他文献
会议
  Medical image segmentation is very important part of medical image processing.The accuracy of image segmentation effect the image feature extraction,classif
会议
  Objective This study aims to provide effective and reliable methods to measure the focus doserate,absolute dose accuracy and position accuracy for gamma-ray
会议
  Purpose:In three dimensional(3D) scanned carbon ion radiotherapy,smaller beam spots are desired owing to their sharper lateral profiles,which definitely red
会议
  Recently horns are considered as potential candidates for various biomedical applications due to their distinct biomechanical properties.We therefore perfor
会议
  Feature extraction and selection plays an important role in classifying systems.This paper is focus on using two models to analyze the CT image of healthy l
会议
会议
  What image feature extract is the basis of image recognition,image data mining,image retrieval,is the most crucial step of pattern recognition and classific
会议
会议
会议