Aim: To compare the visual function in patients with short wavelength blue light blocking yellow tinted intraocular lenses (IOLs) with that in patients with non-tinted IOLs. Methods: 74 patients scheduled for bilateral cataract surgery underwent implantation of either yellow IOLs (HOYA YA60BB) or nontinted IOLs (VA60BB) in both eyes. Contrast visual acuity with and without a glare source was measured under photopic (100 cd/m2) and mesopic (slightly higher luminance than typically used-5 cd/m2) conditions at 2 weeks and 3 months after surgery using the contrast sensitivity accurate tester. Visual acuity and the incidence of patients who noted cyanopsia were also examined. Results: No significant differences between the yellow tinted and non-tinted IOL groups were observed in mean visual acuity or in photopic or higher luminance mesopic contrast visual acuity with and without glare source at either 2 weeks or 3 months after surgery. Furthermore, there was no significant difference in contrast visual acuity loss as a result of glare. The incidence of patients who noticed cyanopsia was significantly less in the yellow tinted IOL group than in the non-tinted IOL group at 2 weeks after surgery (p=0.0234), but no patients reported cyanopsia at 3 months. Conclusion: Visual function in patients with yellow tinted IOLs is virtually the same as that in patients with non-tinted IOLs.
Methods: 74 patients scheduled for bilateral cataract surgery underwent implantation of either yellow IOLs (HOYA YA60BB Contrast visual acuity with and without glare source was measured under photopic (100 cd / m2) and mesopic (slightly higher luminance than typically used-5 cd / m2) conditions at 2 weeks and 3 months after surgery using the contrast sensitivity accurate tester. Visual acuity and the incidence of patients who noted cyanopsia were also examined. Results: No significant differences between the yellow tinted and non-tinted IOL groups were observed in mean visual acuity or in photopic or higher luminance mesopic contrast visual acuity with and without glare source at either 2 weeks or 3 months after surgery. Furthermore, there was no significant difference in con The incidence of patients who noticed cyanopsia was significantly less in the yellow tinted IOL group than in the non-tinted IOL group at 2 weeks after surgery (p = 0.0234), but no patients reported cyanopsia at 3 months. Conclusion: Visual function in patients with yellow tinted IOLs is virtually the same as that in in patients with non-tinted IOLs.