中国科学院近代物理研究所医用重离子加速器(HIMM)高频系统31.02 MHz回旋加速器谐振腔已完成设计加工和腔体的老炼,并投入正常运行。高频腔体的设计峰值Dee电压要求达到70 k V,但是Dee电压准确计算比较困难,可以通过CST仿真软件对腔体进行模拟得到高频腔体的RP/Q0值,结合输入到腔体的实际功率,计算出腔体的实际电压值。为了验证Dee电压的准确性,在相同的腔体输入功率条件下,利用韧致辐射法测量腔体电压,测量结果与计算结果误差在0.6%以内。
Chinese Academy of Sciences Institute of Modern Physics medical heavy ion accelerator (HIMM) high-frequency system 31.02 MHz cyclotron resonator has been completed the design processing and cavity aging, and put into normal operation. The designed peak Dee voltage of the high-frequency cavity needs to reach 70 kV, but it is difficult to calculate the Dee voltage accurately. The cavity can be simulated by the CST simulation software to obtain the RP / Q0 value of the high-frequency cavity, Actual power, calculate the actual voltage value of the cavity. In order to verify the accuracy of the Dee voltage, the chamber voltage was measured by the bremsstrahlung method under the same input power of the cavity. The error between the measurement result and the calculation result was less than 0.6%.