论文部分内容阅读
一、原材料控制称量聚苯板、挤塑板重量,对比合同、外墙保温图集要求,检查密度是否满足要求。检查聚苯板、挤塑板点燃后是否阻燃;粘结砂浆、面层抗裂砂浆不得混用,也不得更换品牌;在合同中约定使用成品滴水线条、成品阳角条,并监督其使用到工程中。二、施工控制1.控制保温板粘结率计算出粘结率40%的具体面积,中间8个
First, the control of raw materials Weigh polystyrene board, extruded board weight, contrast contract, wall insulation atlas requirements, check whether the density meets the requirements. Check the polystyrene board, extruded board lit whether the flame retardant; adhesive mortar, surface cracking mortar may not be mixed, nor change the brand; the contract agreed to use the finished product dripping lines, finished product Yang corner, and to monitor its use Engineering. Second, the construction control 1. Control insulation board bonding rate to calculate the specific area of the bonding rate of 40%, the middle 8