在大修C 3025回轮式六角车床时,要求转盘上的12个孔的轴线分别对主轴回转中心同轴度公差0.02毫米。我们采用了在主轴上安装镗杆进行镗削,分别加工转盘上的各孔。镗削完后,检测其同轴度误差时,我们将百分表座架固定在主轴上进行测量,在被测孔相互垂直位置上,四点的读数分别为:d=0.01。上述结果,可明显看出是由于测量误差所产生的不正确结果。根分析,主要是因为表杆太长,测量过程发生变形而产生测量误差所致。我
When overhauling C 3025 return wheel hexagonal lathe, the axis of the 12 holes on the turret is required to have a tolerance of 0.02 mm on the concentricity of the spindle center of rotation, respectively. We used to install the boring bar in the spindle boring, respectively, each processing turret hole. After boring, to detect the error of its coaxiality, we will be fixed to the spindle on the dial indicator to measure the measured hole perpendicular to each other, the four points were read as: d = 0.01. The above results, it is clear that is due to measurement error caused by incorrect results. Root analysis, mainly because the rod is too long, the measurement process of deformation caused by measurement error. I