论文部分内容阅读
岩棉复合外墙节能试验住宅建在哈尔滨市友谊路住宅小区,按着城巾建筑规划要求,为中高层九层住宅(包括地下室为十层),内设两部楼梯和一部电梯,平面为矩形,建筑面积3793.91m~2,结构体系为横墙承重砖混结构,外墙采用岩棉与粘土砖,石膏板分两种进行组合的岩棉内镶的复合墙体,岩棉厚度按节能热阻需要确定,粘土砖厚度按承重和稳定确定。选择这样的结构体系,虽然外墙的质量降低,蓄热性能差,但由于内墙是密实的重材料,整个房屋的质量较高,蓄热量增加,对保证室内温度环境的
The rock wool composite outer wall energy-saving test house was built in the friendship area of the Friendship Road, Harbin City. According to the requirements of the city towel building planning, it is a high-rise nine-story house (including ten basements) with two staircases and an elevator. It is a rectangular building with a building area of 3,793.91m~2. The structural system is a cross-wall load-bearing brick-concrete structure. The outer wall is made of rock wool and clay bricks, and the gypsum board is divided into two types of rock wool intercalated composite walls. The thickness of rock wool is The thermal resistance of energy saving needs to be determined, and the thickness of clay bricks is determined according to load-bearing capacity and stability. Selecting such a structural system, although the quality of the outer wall is reduced, the thermal storage performance is poor, but because the inner wall is a dense heavy material, the quality of the entire house is high, the heat storage capacity increases, and the indoor temperature environment is guaranteed.