牵引电动机支路内加装分路电流表,是东风型内燃机车两机(柴油机、牵引电机)改造的内容之一。我段在经过这一改造后,经常发生分流表烧毁的现象,严重者竟引起司机室失火。经详细查找及分析原因,找到了问题的所在,并采取了相应的措施。主要原因是在加装分流表时无具体要求,因此,有的单位将分流表加装于牵引电动机正端一侧,这样一来,首先超出了仪表本身的技术要求。因为虽然表面上标注的一个空心☆,表明仪表的绝缘强度试验电压为500伏,然而,实际中牵引电动机的最高工作电压已大大
Traction motor branch to install shunt ammeter, is the Dongfeng diesel locomotive two machines (diesel engine, traction motor) one of the transformation. After the passage of this paragraph, I often had the phenomenon of burned shunt tables. In serious cases, the driver’s cabs actually caught fire. After a detailed search and analysis of the reasons, found the problem, and took corresponding measures. The main reason is the installation of shunt table without specific requirements, therefore, some units will shunt table mounted on the positive side of the traction motor, this way, first of all, beyond the technical requirements of the instrument itself. Because although the surface marked a hollow ☆, indicating the instrument’s dielectric strength test voltage of 500 volts, however, the actual maximum operating voltage of the traction motor has been greatly