本文分析了在 TTL 电路动态(Tpd)自动测试中,环形振荡器法所存在的问题。针对 ECL 电路的特点,有效地运用传输线和已有器件,提出一个基于“环形振荡器法”的测试方案,可不用继电器而进行被测管脚的变换,并克服了 TTL 动态自动测试中的若干问题。对测试误差进行了分析,并指出超高速 ECL 电路动静态联合自动测试的可能性。根据此方案,制作了动态测试盒,配合自装直流参数自动测试仪或数字频率计,对 MECL10K 电路进行了测试,证明对 ECL 组合逻辑电路动态自动测试是可行的,与示波器测试比较,可大大提高工作效率,保证必要的精度,并可使测试条件更接近实际使用情况。
This paper analyzes the problems existing in the ring oscillator method in the automatic test of TTL circuit dynamics (Tpd). According to the characteristics of ECL circuit, the transmission line and the existing devices are effectively used to propose a test scheme based on the “ring oscillator method”, which can change the pin under test without using a relay and overcome some problems in the TTL dynamic automatic test problem. The test error is analyzed, and the possibility of combined dynamic and static testing of ultra-fast ECL circuits is pointed out. According to this scheme, a dynamic test box was made, with self-installed DC parameter automatic tester or digital frequency meter, the MECL10K circuit was tested to prove that the ECL combinational logic circuit dynamic automatic test is feasible, compared with the oscilloscope test can be greatly Improve work efficiency, ensure the necessary accuracy, and make the test conditions closer to the actual use.