点热法是用局部加热校正轴类的弯曲。通常,对于较粗较短的轴类弯曲变形,用普通方法校直是比较困难的,采用点热法校正就容易多了。我厂曾有一台进口镗床,镗杆尺寸为φ110×2000毫米,由于发生事故,离镗杆头部600毫米处弯曲了0.80毫米,我厂机修工人师傅们用了点热法很方便地校正过来了。经检验,误差仅为0.01毫米,到现在为止,使用情况良好,未发现不正常现象。具体的工艺方法如下:
Point heating is the use of local heating correction shaft bending. Normally, for the thicker and shorter shaft bending deformation, it is more difficult to calibrate it by the ordinary method, and it is much easier to calibrate it by the spot calorimetry method. I had a factory in the factory imported boring machine, boring bar size φ110 × 2000 mm, due to an accident, bending 600 mm from the boring bar at a head of 0.80 mm, I plant mechanic who used the point calorimeter is very easy to correct It’s After testing, the error is only 0.01 mm, up to now, the use of good, did not find abnormal. The specific process is as follows: