K-1000血细胞计数仪由水路系统、压缩机和电子系统组成。水路系统主要执行吸样、分配、稀释、混合和溶血等过程。电子系统主要对水路系统所处理的样品中给出的信号进行分析、计算,并通过内置打印机打印出分析、计算的结果。电子系统控制测试的顺序,检查测试的数据,还可借助微处理机控制来执行质量控制。压缩机产生恒定的正压和负压,控制启动。
K-1000 blood cell counter by the water system, compressors and electronic systems. The main implementation of the water system aspiration, distribution, dilution, mixing and hemolysis and other processes. The electronic system mainly analyzes and calculates the signals given in the samples handled by the waterway system and prints out the results of the analysis and calculation through the built-in printer. The electronic system controls the sequence of tests, examines the test data, and performs quality control with microprocessor control. The compressor produces a constant positive and negative pressure, control start.