前几年,我们在经过适当改装的75千瓦的井式气体渗碳炉上进行了滴控渗碳的实验研究。在实验过程中,炉气的连续测定采用上海第二分析仪器厂的 HQG-71型红外线 CO_2分析仪;炉气的全分析采用上海分析仪器厂的102-G 气相色谱分析仪,碳势的自控系统如图1所示。经反复实验和较长时间的实际使用证明;CO_2的自控精度可稳定在±0.015%(或±0.01%)以内;碳势的自控精度可稳定在±0.05%以内。从实验和使用情况来看,其渗
A few years ago, we conducted an experimental study of dripping carburizing on a properly retrofitted 75 kW pit gas carburizing furnace. In the process of experiment, continuous measurement of furnace gas was made by HQG-71 infrared CO_2 analyzer of Shanghai No.2 Analytical Instrument Factory. The full analysis of furnace gas was carried out by Shanghai Analytical Instrument Factory’s 102-G gas chromatograph, System shown in Figure 1. After repeated experiments and the actual use of a long time to prove that; CO_2 self-control accuracy can be stabilized within ± 0.015% (or ± 0.01%) or less; carbon potential accuracy can be controlled within ± 0.05%. From the experiment and use of view, its infiltration