论文部分内容阅读
建立了测定蛛网膜下腔出血患者(SAH)脑脊液中血小板活化因子(PAF)质量浓度的高效薄层扫描方法。薄层板为高效硅胶G板(100 m m ×100 m m ),展开剂为V(氯仿)vV(甲醇)vV(水)= 65v35v6,下层液展开,显色剂为100 g/L磷钼酸溶液,展开距90 m m ,扫描波长630 nm 。方法的线性范围0.5 ~2.5 μg/L,相关系数0.999 0,最小检测质量浓度50 ng/L,平均回收率98.6% 。运用所建立的方法测定了16例SAH患者发病后脑脊液和10例非神经系统疾病患者脑脊液中PAF的质量浓度及其变化规律,为临床提供了诊断依据。
A high-performance thin-layer scanning method for the determination of platelet-activating factor (PAF) in cerebrospinal fluid of patients with subarachnoid hemorrhage (SAH) was established. The TLC plate was a high efficiency silica gel G plate (100 m × 100 m m). The developing agent was V (chloroform) vV (methanol) vV (water) = 65 v35v6. Acid solution, developed 90 m m away, scanning wavelength 630 nm. The linear range of the method was 0.5-2.5 μg / L with a correlation coefficient of 0.999 0. The minimum detectable concentration was 50 ng / L and the average recovery was 98.6%. The established method was used to determine the concentration and variation of PAF in cerebrospinal fluid of 16 patients with SAH after onset and 10 patients with non-neurological diseases, which provided the basis for clinical diagnosis.