铁氰复盐在工业生产上有广泛的用途,虽然这类化合物本身毒性甚微,但其分解产物游离氰化物对鱼类及腐败微生物均有毒害,因而测定铁氰复盐溶液中游离氰氢酸已成为一个重要的问题。本文提出了康威氏皿扩散法,从含有铁氰复盐的污水样品中分离游离氰化物,而后进行测定。此法简单易行,不需特殊仪器,可在控制pH条件下进行分离,因此适用于常规分析,其操作方法如下:吸取1.5N氢氧化钾溶液6毫升,加入康威氏皿中心池内,另取pH7磷酸二氢钾-氢氧化钠缓冲液5毫升于皿的外池。
Ferricyanide complex salt has a wide range of uses in industrial production. Although the compounds themselves have little toxicity, free cyanide, which is a decomposition product, is poisonous to fish and spoilage microorganisms. Therefore, the determination of free cyanide in ferricyanide double salt solution Acids have become an important issue. This article presents the Convarsch dish diffusion method for the separation of free cyanide from sewage samples containing ferricyanide complex salts and subsequent measurements. This method is simple, without special equipment, can be separated in the control of pH conditions, it is suitable for routine analysis, the method of operation is as follows: draw 1.5N potassium hydroxide solution 6 ml, join Kang Weishi dish central pool, and the other Take pH7 potassium dihydrogen phosphate - sodium hydroxide buffer 5 ml in the outer pool of the dish.