论文部分内容阅读
Micro-stepping motion of ultrasonic motors satisfies biomedical applications,such as cell operation and nuclear magnetic resonance,which require a precise compact-structure non-magnetization positioning device.When the pulse number is relatively small,the stopping characteristics have a non-negligible effect on the entire stepwise process.However,few studies have been conducted to show the rule of the open-loop stepwise motion,especially the shutdown stage.In this study,the modal differences of the shutdown stage are found connected with amplitude and velocity at the turn-off instant.Changes of the length in the contact area and driving zone as well as the input currents,vibration states,output torque,and axial pressure are derived by a simulation model to further explore the rules.The speed curves and vibration results in functions of different pulse numbers are compared,and the stepwise motion can be described by a two-stage two-order transfer function.A test workbench based on the Field Programmable Gate Array is built for acquiring the speed,currents,and feedback voltages of the startup-shutdown stage accu-rately with the help of its excellent synchronization performances.Therefore,stator vibration,rotor velocity,and terminal displacements under different pulse numbers can be compared.Moreover,the two-stage two-order model is identified on the stepwise speed curves,and the fitness over 85% between the simulation and test verifies the model availability.Finally,with the optimization of the pulse number,the motor achieves 3.3 μrad in clockwise and counterclockwise direction.