论文部分内容阅读
非透明围护结构的传热系数和窗墙面积比是影响围护结构节能的两个重要方面,机组的性能系数是系统节能的重要参数。以公共建筑模型数据库为研究对象,采用不同类型公共建筑在同一气候区的分布特征加权后的计算结果作为评价该气候区公共建筑整体性能的依据。采用单因素变量分析方法,对相同的节能措施在不同气候区产生的节能效果进行计算研究,从而对节能技术的地区适应性进行评价,单一节能措施节能量的量化分析结果能直接反映该节能措施在该气候区的适用性。
The heat transfer coefficient and the window wall area ratio of the non-transparent enveloping structure are two important aspects that affect the energy saving of the enveloping structure. The performance coefficient of the aircrew is an important parameter for energy saving of the system. Taking the public building model database as the research object, the weighted results of the distribution characteristics of different types of public buildings in the same climate area are used as the basis for evaluating the overall performance of public buildings in this climate area. The univariate analysis of variables is used to calculate the energy saving effect of the same energy saving measures in different climatic zones so as to evaluate the regional adaptability of energy saving technologies. The quantitative analysis results of energy saving of single energy saving measures can directly reflect the energy saving measures Applicability in this climatic zone.