一些城市由于直接利用自来水管网给高层建筑供水和解决消防用水已不能满足要求。因此,有的高层建筑在设计阶段中采用加大屋顶水箱容量的办法,这不仅造成建筑结构上的肥梁胖柱,使基建投资增加,而且还影响建筑的美观和使用,特别是在供水低谷时,给高位水箱自然补水已没有保证。为此,我们为某工程设计了地下水池和高位水箱的供水系统。这一系统虽说增加了地下水
In some cities, the direct use of the water supply network to supply water to high-rise buildings and to solve fire-fighting water is no longer sufficient. Therefore, some high-rise buildings adopt the method of increasing the capacity of the roof water tank during the design phase. This not only results in fat pillars on the structure of the building, but also increases the investment in infrastructure. It also affects the beauty and the use of the building, especially in the water supply. At this time, there is no guarantee that natural water supply to the high water tanks will be available. For this reason, we have designed a water supply system for underground water tanks and high water tanks for a project. Although this system increased groundwater