论文部分内容阅读
针对三种细丝热电偶温度传感器的结构特点进行了分析,并通过动态特性试验与理论计算结果的对比分析,得出理论计算与试验结果偏差小于10%,可以利用推荐的经验公式进行细丝热电偶动态特性计算预测的结论。
The structural characteristics of the three kinds of filament thermocouple temperature sensors are analyzed. By comparing the dynamic characteristic test with the theoretical calculation results, the deviation between the theoretical calculation and the experimental result is less than 10%. The recommended empirical formula can be used to make the filament Thermocouple dynamic characteristics of the calculation and prediction of the conclusion.