论文部分内容阅读
我们采用DiasonicSPA1000(10MHzDuplex)超声仪.连接计算机AST386(扩展槽内插VFG-512.BC图像板).用VFG二维视频图像处理程序(C语言),将灰阶图像转为四段编码B彩图,回声强弱以红→黄→绿→兰色。作者认为彩阶图可弥补肉眼对灰阶图认识不足,使操作者对微小病变区的观察更为直观。现将资料完整的经手术或病理证实的109眼作一回顾性分析。彩阶图所显示的病例完全符合手术或病理诊断。
We use DiasonicSPA1000 (10MHzDuplex) ultrasound system. Connect computer AST386 (expansion slot to interpolate VFG-512.BC image board). VFG two-dimensional video image processing program (C language), the gray-scale images into four sections of B-color images, the echo strength of red → yellow → green → blue. The author believes that the color-sequence images can make up for the lack of understanding of the gray-scale images by the naked eye, and make the operator more intuitively observe the tiny lesion areas. Now complete data of 109 cases confirmed by surgery or pathology for a retrospective analysis. The cases shown in the color image are completely consistent with the surgical or pathological diagnosis.