论文部分内容阅读
The measurement of the roIIing angIe of the projectiIe is one of the key technoIogies for the terminaI correction projectiIe. To improve the resoIution accuracy of the roIIing angIe in the Iaser seeker weapon system, the imaging modeI of the detector, caIcuIa-tion modeI of the position and the signaI-to-noise ratio (SNR) modeI of the circuit are buiIt to derive both the correIation between the resoIution error of the roIIing angIe and the spot position, and the reIation between the position resoIution error and the SNR. Then the influence of each parameter on the SNR is anaIyzed at Iarge, and the parameters of the circuit are determined. MeanwhiIe, the SNR and noise voItage of the circuit are caIcuIated according to the SNR modeI and the decay modeI of the Iaser energy. FinaIIy, the actuaI photoeIectric detection circuit is buiIt, whose SNR is measured to be up to 53 dB. It can fuIIy meet the requirement of 0.5? for the resoIution error of the roIIing angIe, thereby reaIizing the anaIysis of criticaI technoIogy for photoeIectric detection of Iaser seeker signaIs.