在酸性介质中,高锰酸钾氧化甲醛产生化学发光信号,当该体系中存在多巴胺时,体系发光信号显著增强,基于这一现象,建立了一种简单快速测定多巴胺的流动注射化学发光新方法。并且对试验条件进行优化。在最优条件下,多巴胺在6.0×10-8—2.0×10-5mol/L范围内与发光强度呈良好的线性关系,检出限是2.0×10-8mol/L。对2.0×10-6mol/L的多巴胺标准溶液平行测定11次,平行测得值的RSD为3.4%。将本法用于血浆中多巴胺的测定,结果令人满意。
In acidic medium, potassium permanganate oxidizes formaldehyde to generate chemiluminescence signal. When dopamine is present in the system, the luminescence signal of the system is significantly enhanced. Based on this phenomenon, a new flow-injection chemiluminescence method for the determination of dopamine is established. . The test conditions were optimized. Under optimal conditions, dopamine showed a good linear relationship with the luminescence intensity in the range of 6.0 × 10-8-2.0 × 10-5mol / L with a detection limit of 2.0 × 10-8mol / L. 11 times the standard solution of 2.0 × 10-6mol / L dopamine parallel determination of RSD was 3.4%. This method is used for the determination of dopamine in plasma with satisfactory results.