论文部分内容阅读
CYCIAE-100强流回旋加速器因为其磁极间气隙小,主磁铁的内部缺陷、机械加工的误差和安装误差等因素对中心平面的磁场分布的影响就相对明显,因此需要对主磁铁的磁场进行精确测量与垫补。磁场精确测量的基础是要设计一套高精度的磁场测量仪,本文对这套磁场测量仪的机械设计进行了简要描述。1磁场测量的要求100MeV回旋加速器主磁铁磁场测量要求设计一套精密的、高度自动控制的磁场测量装置以及
CYCIAE-100 high-intensity cyclotron has a relatively obvious influence on the magnetic field distribution of the central plane because of the small air gap between the magnetic poles, the internal defects of the main magnet, machining errors and installation errors, etc. Therefore, the magnetic field of the main magnet needs to be made Accurate measurement and padding. The precise measurement of the magnetic field is based on the design of a set of high-precision magnetic field measuring instruments. In this paper, the mechanical design of the magnetic field measuring instrument is briefly described. 1 Magnetic Field Measurement Requirements The 100MeV cyclotron main magnet field measurement requires the design of a sophisticated, highly automated magnetic field measurement device and