前言葛洲坝水利枢纽第一期主体工程混凝土建筑物由三号船闸、冲沙闸、二号船闸、非溢流坝、电站厂房和泄水闸组成。在施工过程中,不少部位的混凝土产生了裂缝。据初步统计,截至1980年4月25日为止,先后检查发现混凝土裂缝3456条,其中绝大部分为表面裂缝。施工过程中在浇筑层顶面发现的裂缝基本上都作了布筋处理(约1295条)。表面裂缝降低建筑物的耐久性;深度较大的裂缝影响建筑物的整体性,不利于建筑物的稳定。因此,对影响建筑物安全的混凝土裂缝必须进行补强处理。
Preface Gezhouba Water Control Project Phase I of the main concrete structures from the third ship lock, red sand gate, the second ship lock, non-overflow dam, power plant and sluice gate composition. In the construction process, many parts of the concrete cracks. According to preliminary statistics, up to April 25, 1980, it has successively inspected 3,456 concrete cracks, of which the vast majority are surface cracks. During the construction process, the cracks found on the top of the pouring layer were basically reinforced (about 1295 pieces). Surface cracks reduce the durability of the building; depth cracks affect the integrity of the building is not conducive to the stability of the building. Therefore, concrete cracks that affect the safety of buildings must be reinforced.