论文部分内容阅读
本文采用高压液相色谱法测定心痛定片剂与滴丸的人体血药浓度。流动相:甲醇(色谱纯)─磷酸盐缓冲液(60:40),紫外检测波长235nm,以片剂为标准制剂,滴丸的相对生物利用度为122.0%。对片剂与滴丸的AUC、Cmax、Tmax作t检验,结果二者之间Cmax、Tmax有显著性差异(P<0.05),AUC无显著差异(P>0.05),结果表明滴丸较片剂优良。
In this paper, high-pressure liquid chromatography determination of the heart of the drug tablets and drops of human plasma concentration. The mobile phase consisted of methanol (pure chromatography) -phosphate buffer (60:40) and UV detection wavelength of 235 nm. The tablet’s standard formulation showed that the relative bioavailability of dropping pills was 122.0%. The AUC, Cmax, Tmax of tablet and dropping pills were tested by t test. The results showed that there was significant difference between Cmax and Tmax (P <0.05) and no significant difference of AUC (P> 0.05) Dropping pills are better than tablets.