论文部分内容阅读
摘要: 苘山水厂是威海市最大规模的自来水厂,建设规模为一期10万m3/日,二期20万m3/日。水厂建设过程中,我们在滤池部分选用了挪威进口的膨胀粘土取代了国产石英砂作为滤料,这一举措充分利用该滤料表面积大,截污能力强的特点在实际运行中实现省电省水的节能目标。本项目是进口膨胀粘土滤料用于国内水厂的首个工程实例。
关键词:水厂整浇滤板进口滤料膨胀粘土
Abstract: Qing landscape Factory is the largest water plant in Weihai City, the scale of construction of a 100,000 m3 / day, two 200,000 m3 / day. Waterworks construction process, we selected in the filter part of the expanded clay of Norwegian imports replace domestic quartz sand as a filter, this initiative take full advantage of the large surface area and interception in ability of the filter characteristics in the actual operation Province electric water-saving energy efficiency goals. This project is imported expanded clay filter for domestic water treatment plant the first instance.Keywords: Water integral casting filter plate import filter expanded clay
中图分类号: TU991文献标识码:A 文章编号:
概述
“城市发展,供水先行”。近年来,随着威海市经济的发展和人口的增多,供水需求矛盾突出,供水设施运转已趋饱和。威海市内原有自来水厂规模较小,水源输水量不足,为缓解水危机,保障市民生活供水充足,市政府及相关部门启动了从米山水库调水的米威三期引水工程。该工程由威海市水务集团有限公司投资,由我公司承建,于2008年开工建设。工程计划总投资4.9亿元,主要包括苘山净水厂、米山水库取水泵站和输配水管网三部分。
苘山净水厂建设规模为一期10万m3/日;二期20万m3/日,占地9.6公顷。建设内容主要为常规处理和排泥水处理系统两部分。原水自米山水库经原水提升泵房提升后进入苘山净水厂主体处理工艺流程。水厂采用混凝、沉淀、过滤、消毒的加强常规处理工艺,出水通过提升泵房和重力自流输水形式进行分别向东西两线供水,并预留二期及深度处理设施用地。
建设过程中,我们在加氯,加药,滤池和泵房等工艺核心部分均选择了进口设备,在沉淀,污泥处理,管网等其它各个部分也选用了国内优秀厂家的产品。尤其是滤池部分采用了挪威进口的膨胀粘土取代了国产石英砂作为滤料,这一举措充分考虑了将来可能取黄河水作为原水,黄河水质不断变化的因素,确保出水水质完全达到或者超过国家饮用水标准,并利用该滤料表面积大,截污能力强的特点在实际运行中实现省电省水的节能目标。
米威三期引水工程于2010年竣工,使得威海市区总供水能力达到31万m3/日,其配套供水管线工程与市区原供水管道形成大环路,从而使城市供水布局更加科学、合理,供水安全保障能力进一步提高,服务全市经济社会发展的战略支撑作用更加突出。
工艺流程及设备选型
苘山净水厂是米威三期引水工程的核心项目,出水水质指标全部达到或优于国家新颁布的生活饮用水水质标准。
水厂为加强常规处理工艺设计,采用强化混凝、沉淀、过滤和消毒处理工艺,并预留深度处理用地位置。
根据流程布局,原水经米山水库的原水提升泵房提升送入水厂管道混合器井。原水提升泵房位于米山水库泵站。
原水进入水厂后,先进入加氯加药区。水厂的加氯加药设备全部采用德国进口的国际知名品牌。它的优点是产品质 量可靠,运行安全性高,售后服务好,并且加氯加药量经过比例环控制器精确测算,可以有效降低整套系统的运行成本。
之后进入反应池部分。我们选用小孔网格反应设备来完成絮凝过程,使具有絮凝性能的微絮粒相互接触碰撞,从而形成更大的絮粒,以适应沉降分离的要求。水通过穿孔花墙后产生的大涡旋变成较多的小涡旋,从而消除了水中细小的矾花,有效的提高平流沉淀池的处理能力。
之后进入滤池。滤池布水布气采用长柄滤头和整体钢筋砼现浇滤板,突破了传统滤头用小块滤板的水平度来控制滤头水平,以达到布气配水均匀的效果,避免了预置滤板施工难度大,以及普遍存在的滤板缝隙不严密、 漏砂翻板等隐患。滤池部分的滤料从挪威进口,国内水厂首家使用。该滤料截污能力强,而且可以有效降低反冲洗次数,节水节电效果非常显著。
滤池是水厂的核心工艺部位,主要設备反冲洗风机和反冲洗水泵分别选用了国际知名品牌和威海当地的名牌产品,这两个品牌在国内大型水厂和工业企业应用广泛,具有可靠性高、能耗低等优点。
闸门和阀门均配备气动执行装置,压缩空气气源来自反冲洗泵房内的空压机组。
实际运行中,考虑对滤池初滤水进行排放,通过每格滤池的出水阀门的调节,将初滤水接出至专设的初滤水排放管输送到回流调节池以便循环利用。
本项目建设范围包括水厂自动控制系统、在线检测仪表,CCTV系统和安保系统。为了保证处理装置稳定运行和水量计量准确,我们在沉淀清水池和V型滤池等主要部位均安装了进口并在业内具有很高知名度品牌的在线仪表检测装置,能够及时发现故障部位并予以排除。
在水厂整个设计和建设过程中充分贯彻了“零排放”的环保理念。滤池反冲洗废水和浓缩池上清液由废水调节池收集,由沉淀池入口进入处理系统;污泥脱水系统对沉淀池排泥水进行脱水,滤后液回流至前储泥池,这样实现了全厂废水的再回收和再处理,无废水外排。
施工难点
在净水构筑物的滤池结构中,滤池的配水、布气系统的成功与否是至关重要的,尤其是气水反冲工艺对配水、布气系统的施工水平有更高的要求。
为了实现整体浇筑混凝土滤板,必须有不拆卸的成型板材(采用食品级ABS板)制作凹凸型模板,能可靠支撑整体浇筑工程的施工荷载。在模板安装后钢筋骨架采用φ10或φ12与池壁钢筋联接为一体。
混凝土养护后,在滤头预埋件(滤座)内插入可调节螺杆,其可调螺距为70mm,供滤池长期运行后可能出现土建构筑物不均匀沉降时可调节使用,调节精度(最小调节量)为0.4mm。
滤池布水区进水,根据水面来调节滤杆的上端平面在同一水平高度,从而保证进气孔在同一水平线上。
采用防松动自锁滤头予以联接滤座,由于整体浇筑滤板的模板是定型的,所以滤头之间的距离和每平方米布置的滤头数量也是固定的,而标准型滤头的缝隙面积也统一,从而全池开孔比也是固定的。
支撑梁柱浇注、梁面找平、模板安装、钢筋绑扎、混凝土浇注、滤杆安装及调节滤杆水平度和布气布水均匀性调试及验收必须由有资格的人员按照来进行。
工程心得
单体设备的招标 – 采购到合适的设备的情况下降低建设成本
本项目为威海财政项目,因此采用总包单独招标各工艺设备的设备采购方式。首先由我司按工程要求达到的性能指标和边界条件编制标书,在标书中确立设备的性能指标要求,然后组织投标,最后依据评分标准进行评标并和供应商签订合同。
建设过程中的质量控制–建设的根本,将来运行的基础虽然供应商对各自供应的设备承担质量责任,但是作为总承包商,我们对工程性能、质量承担全部责任,并对建设过程进行全方位的质量控制。在整个施工过程中以施工图为基础配合业主、质检和监理单位进行质量控制和管理。
自控建设应注意的问题 –现代化水厂运行的核心系统现代化水厂的自控要求很高,因此要特别引起注意。一是定位要正确。自动到什么水平要根据需要并量力而行,不能盲目地追求全自动。二是对设备的选择要以我为主,首先要求高可靠、高质量;既引进国外先进设备也不排斥国内先进设备。三是对一次仪表要重点关注。对水厂自控来说,PLC和计算机的可靠度已经相当高,因此一次仪表选择是自控系统能否正常运转的关键所在。在整个建设过程中,我们牢牢的按照这几个基本思路执行,并最终取得了不错的效果。
结论
在整个水厂建设过程中,我们将多年来致力于国内大型城市水厂和污水厂建设的工程和其它技术经验应用于本项目中,围绕“建精品工程、创一流水厂”的总体构想,很好地确保了水厂工程建设的顺利进行。
关键词:水厂整浇滤板进口滤料膨胀粘土
Abstract: Qing landscape Factory is the largest water plant in Weihai City, the scale of construction of a 100,000 m3 / day, two 200,000 m3 / day. Waterworks construction process, we selected in the filter part of the expanded clay of Norwegian imports replace domestic quartz sand as a filter, this initiative take full advantage of the large surface area and interception in ability of the filter characteristics in the actual operation Province electric water-saving energy efficiency goals. This project is imported expanded clay filter for domestic water treatment plant the first instance.Keywords: Water integral casting filter plate import filter expanded clay
中图分类号: TU991文献标识码:A 文章编号:
概述
“城市发展,供水先行”。近年来,随着威海市经济的发展和人口的增多,供水需求矛盾突出,供水设施运转已趋饱和。威海市内原有自来水厂规模较小,水源输水量不足,为缓解水危机,保障市民生活供水充足,市政府及相关部门启动了从米山水库调水的米威三期引水工程。该工程由威海市水务集团有限公司投资,由我公司承建,于2008年开工建设。工程计划总投资4.9亿元,主要包括苘山净水厂、米山水库取水泵站和输配水管网三部分。
苘山净水厂建设规模为一期10万m3/日;二期20万m3/日,占地9.6公顷。建设内容主要为常规处理和排泥水处理系统两部分。原水自米山水库经原水提升泵房提升后进入苘山净水厂主体处理工艺流程。水厂采用混凝、沉淀、过滤、消毒的加强常规处理工艺,出水通过提升泵房和重力自流输水形式进行分别向东西两线供水,并预留二期及深度处理设施用地。
建设过程中,我们在加氯,加药,滤池和泵房等工艺核心部分均选择了进口设备,在沉淀,污泥处理,管网等其它各个部分也选用了国内优秀厂家的产品。尤其是滤池部分采用了挪威进口的膨胀粘土取代了国产石英砂作为滤料,这一举措充分考虑了将来可能取黄河水作为原水,黄河水质不断变化的因素,确保出水水质完全达到或者超过国家饮用水标准,并利用该滤料表面积大,截污能力强的特点在实际运行中实现省电省水的节能目标。
米威三期引水工程于2010年竣工,使得威海市区总供水能力达到31万m3/日,其配套供水管线工程与市区原供水管道形成大环路,从而使城市供水布局更加科学、合理,供水安全保障能力进一步提高,服务全市经济社会发展的战略支撑作用更加突出。
工艺流程及设备选型
苘山净水厂是米威三期引水工程的核心项目,出水水质指标全部达到或优于国家新颁布的生活饮用水水质标准。
水厂为加强常规处理工艺设计,采用强化混凝、沉淀、过滤和消毒处理工艺,并预留深度处理用地位置。
根据流程布局,原水经米山水库的原水提升泵房提升送入水厂管道混合器井。原水提升泵房位于米山水库泵站。
原水进入水厂后,先进入加氯加药区。水厂的加氯加药设备全部采用德国进口的国际知名品牌。它的优点是产品质 量可靠,运行安全性高,售后服务好,并且加氯加药量经过比例环控制器精确测算,可以有效降低整套系统的运行成本。
之后进入反应池部分。我们选用小孔网格反应设备来完成絮凝过程,使具有絮凝性能的微絮粒相互接触碰撞,从而形成更大的絮粒,以适应沉降分离的要求。水通过穿孔花墙后产生的大涡旋变成较多的小涡旋,从而消除了水中细小的矾花,有效的提高平流沉淀池的处理能力。
之后进入滤池。滤池布水布气采用长柄滤头和整体钢筋砼现浇滤板,突破了传统滤头用小块滤板的水平度来控制滤头水平,以达到布气配水均匀的效果,避免了预置滤板施工难度大,以及普遍存在的滤板缝隙不严密、 漏砂翻板等隐患。滤池部分的滤料从挪威进口,国内水厂首家使用。该滤料截污能力强,而且可以有效降低反冲洗次数,节水节电效果非常显著。
滤池是水厂的核心工艺部位,主要設备反冲洗风机和反冲洗水泵分别选用了国际知名品牌和威海当地的名牌产品,这两个品牌在国内大型水厂和工业企业应用广泛,具有可靠性高、能耗低等优点。
闸门和阀门均配备气动执行装置,压缩空气气源来自反冲洗泵房内的空压机组。
实际运行中,考虑对滤池初滤水进行排放,通过每格滤池的出水阀门的调节,将初滤水接出至专设的初滤水排放管输送到回流调节池以便循环利用。
本项目建设范围包括水厂自动控制系统、在线检测仪表,CCTV系统和安保系统。为了保证处理装置稳定运行和水量计量准确,我们在沉淀清水池和V型滤池等主要部位均安装了进口并在业内具有很高知名度品牌的在线仪表检测装置,能够及时发现故障部位并予以排除。
在水厂整个设计和建设过程中充分贯彻了“零排放”的环保理念。滤池反冲洗废水和浓缩池上清液由废水调节池收集,由沉淀池入口进入处理系统;污泥脱水系统对沉淀池排泥水进行脱水,滤后液回流至前储泥池,这样实现了全厂废水的再回收和再处理,无废水外排。
施工难点
在净水构筑物的滤池结构中,滤池的配水、布气系统的成功与否是至关重要的,尤其是气水反冲工艺对配水、布气系统的施工水平有更高的要求。
为了实现整体浇筑混凝土滤板,必须有不拆卸的成型板材(采用食品级ABS板)制作凹凸型模板,能可靠支撑整体浇筑工程的施工荷载。在模板安装后钢筋骨架采用φ10或φ12与池壁钢筋联接为一体。
混凝土养护后,在滤头预埋件(滤座)内插入可调节螺杆,其可调螺距为70mm,供滤池长期运行后可能出现土建构筑物不均匀沉降时可调节使用,调节精度(最小调节量)为0.4mm。
滤池布水区进水,根据水面来调节滤杆的上端平面在同一水平高度,从而保证进气孔在同一水平线上。
采用防松动自锁滤头予以联接滤座,由于整体浇筑滤板的模板是定型的,所以滤头之间的距离和每平方米布置的滤头数量也是固定的,而标准型滤头的缝隙面积也统一,从而全池开孔比也是固定的。
支撑梁柱浇注、梁面找平、模板安装、钢筋绑扎、混凝土浇注、滤杆安装及调节滤杆水平度和布气布水均匀性调试及验收必须由有资格的人员按照来进行。
工程心得
单体设备的招标 – 采购到合适的设备的情况下降低建设成本
本项目为威海财政项目,因此采用总包单独招标各工艺设备的设备采购方式。首先由我司按工程要求达到的性能指标和边界条件编制标书,在标书中确立设备的性能指标要求,然后组织投标,最后依据评分标准进行评标并和供应商签订合同。
建设过程中的质量控制–建设的根本,将来运行的基础虽然供应商对各自供应的设备承担质量责任,但是作为总承包商,我们对工程性能、质量承担全部责任,并对建设过程进行全方位的质量控制。在整个施工过程中以施工图为基础配合业主、质检和监理单位进行质量控制和管理。
自控建设应注意的问题 –现代化水厂运行的核心系统现代化水厂的自控要求很高,因此要特别引起注意。一是定位要正确。自动到什么水平要根据需要并量力而行,不能盲目地追求全自动。二是对设备的选择要以我为主,首先要求高可靠、高质量;既引进国外先进设备也不排斥国内先进设备。三是对一次仪表要重点关注。对水厂自控来说,PLC和计算机的可靠度已经相当高,因此一次仪表选择是自控系统能否正常运转的关键所在。在整个建设过程中,我们牢牢的按照这几个基本思路执行,并最终取得了不错的效果。
结论
在整个水厂建设过程中,我们将多年来致力于国内大型城市水厂和污水厂建设的工程和其它技术经验应用于本项目中,围绕“建精品工程、创一流水厂”的总体构想,很好地确保了水厂工程建设的顺利进行。