本文通过对空气—水热泵空调系统的动态模拟和实验研究 ,分析了环境空气干、湿球温度变化及低温热源侧换热器结霜对热泵系统工作性能的影响 ,并提出了克服这些影响的技术措施
In this paper, through the dynamic simulation and experimental study of air-water heat pump air-conditioning system, the influence of ambient air dry and wet bulb temperature changes and low temperature heat source side heat exchanger frosting on the performance of heat pump system are analyzed. Technical measures