论文部分内容阅读
1 故障现象:红外探头的灯不亮,调节25W,50W转换开关,亮度调节电位器无效。2 分析检修:该仪整机其摄像、监视功能均正常,因此,故障仅与红外光源通路及控制部件有关,通常有4种原因1.光源灯损坏;2.光源功率变换、调节开关失灵;3.红外光源处理及控制电路板控制失效;4.电路板供电电源故障。根据上述分析,首先怀疑灯泡损坏,打开机外探头,发现探头内除灯泡外,还有一个DC 12V的直流散热风机,经测试该风机正常,更换新灯泡,开机故障依旧;没有听到风机转动声,怀疑是主机箱没有对探头供电,打开主机箱开机测风机两引线,果然没有DC 12V电压存在,按
1 Failure phenomenon: The light of the infrared probe is not on, adjust 25W, 50W switch, brightness adjustment potentiometer is invalid. 2 Analytical overhaul: The instrument’s camera and monitor functions are all normal. Therefore, the fault is only related to the infrared light source path and control components. There are usually four reasons. Light source lamp is damaged; 2. Light source power conversion, adjustment switch failure; 3. Infrared light source processing and control circuit board control failure; Circuit board power supply failure. According to the above analysis, the bulb was first suspected to be damaged, and the external probe was turned on. In addition to the bulb inside the probe, there was also a DC 12V DC cooling fan. After the test, the fan was normal, and the new bulb was replaced. The power failure was still the same; no fan rotation was heard. Sound, suspicion is that the main box does not supply power to the probe. Open the main box and turn on the two leads of the fan. Sure enough, there is no DC 12V voltage. Press