400米~3液态烃球罐裂纹补焊使用了四年时间的400米~3液态烃球罐,开罐检查时,发现4号球板上温带与赤道带环缝裂纹,其长度达1100毫米,最深处24毫米。经金相显微分析,属于使用过程中产生的延迟裂纹。这与施工时,焊前没有预热,焊缝冷却速度过快,加之焊缝不规则,咬边严重而产生的应力集中分不开的,是在长期硫化氢腐蚀介质作用下产生的。为确保补焊质量,我们设计制造了电加热装置——瓦型电炉,如下图。
400 meters ~ 3 liquid hydrocarbon spherical tank crack repair using a four-year period of 400 meters to 3 liquid hydrocarbon spherical tank, open the tank inspection, found No. 4 ball on the temperate and equatorial zone with circumferential cracks, the length of 1100 mm , The deepest 24 mm. Metallographic microscopic analysis, belonging to the use of the process of delayed cracks. This is with the construction, there is no preheating before welding, welding seam cooling too fast, combined with irregular welds, undercut serious stress generated inseparable, is the result of long-term hydrogen sulfide corrosion medium. To ensure the welding quality, we design and manufacture of electric heating device - watt-type electric furnace, as shown below.