论文部分内容阅读
本文提出了测定钼的新极谱体系,最佳底液条件为pH2.1的盐酸-2.37×10-6mol/L桑色素-0.172mol/L氯酸钠。极谱波峰电位为-0.43V(vs.SCE),钼(Ⅵ)浓度在1.04×10-9~4.59×10-8mol/L范围内与波高有线性关系,检出限3.67×10-10mol/L。方法简便,快速、准确,并且直接应用于钨精矿中微量钼的测定。
In this paper, a new polarographic system for the determination of molybdenum is proposed. The optimal conditions for the determination of molybdenum are as follows: hydrochloric acid at pH2.1 -2.37 × 10-6mol / L morin-0.172mol / L sodium chlorate. The polarographic peak potential was -0.43 V (vs.SCE) and the molybdenum (VI) concentration was linear with the wave height in the range of 1.04 × 10-9 ~ 4.59 × 10-8 mol / L with the detection limit of 3 .67 × 10-10mol / L. The method is simple, rapid and accurate, and it can be directly applied to the determination of trace molybdenum in tungsten concentrates.