A SIMULATION STUDY OF ENERGY AND CONDENSATION OF CHILLED BEAM SYSTEM IN THE OFFICE BUILDING

来源 :2016冷冻空调亚洲大会(8th Asian Conference on Refrigeration and Air-c | 被引量 : 0次 | 上传用户:liangpask
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  This simulation study aims at the energy and condensation analysis of chilled beam system in the office building in Taiwan,where is in hot and humid climate.EnergyPlus simulation program is used in this research.It discusses not only the energy performance,but also the chilled beams coil condensation situation and the effect of infiltration at sunny and rainy day of summer.We compared energy performance of variable air volume system and chilled beam system.This study provides designers and owners performance in detail about chilled beam system.The results show that the energy saving percentage of the chilled beam system is 12.7%compared with the variable air volume system.
其他文献
The Green Building movement is driving the HVAC community to look at innovative solutions for reducing the energy cost and better IEQ(Indoor Environment Quality).The ventilation and air conditioning s
会议
Ice slurry is a really interesting technology thanks to the high energy storage density given by the latent heat of phase change and the fast cooling rate because of the large heat transfer surface ar
会议
The use of CFCs and HCFCs is severely restricted and,in an effort to protect the ozone layer,they are being replaced with HFCs.However,leakage of this refrigerant into the air from active or end-of-li
会议
Small diameter copper tubes(5 mm and even less)have been widely applied in refrigeration and air conditioning appliances due to low refrigerant charge and cost saving.However,the small diameter copper
会议
A standard is a document that provides requirements,specifications,guidelines or characteristics that can be used consistently to ensure that materials,products,processes and services are fit for thei
会议
This study employs the particle swarm optimization algorithm to determine the optimum operation of each refrigerant compressor unit within the refrigeration system to obtain the most energy-saving ope
会议
This study investigates the heat and mass transfer performance of the dehumidification system under periodic change of environmental pressure by simulation.Based on some available literatures,in order
会议
Permanent magnet(PM)motors which are operated by the variable frequency drive have the superior efficiency to traditional induction motors(IMs).Therefore,PM motors have been widely adopted in the indu
会议
Chiller is among the most power consuming equipment in a centralized air conditioning system.It provides chilled water for comfort cooling in buildings and manufacturing processes in a factory.In Taiw
会议
This article presents the energy saving retrofit implements and operating analysis of the HVAC system in ITRI biomedical factory.The system adopts heat pump rather than electrical heater to provide ho
会议