Background, Motivation and Objective A potential application of High Intensity Focused Ultrasound (HIFU), guided by either diagnostic ultrasound or MRI, is the ablation of tumor cells in abdominal organs. A major challenge for this particular application is that the volumetric ablation rate, using current clinical equipment and sonication protocols operating below the stable cavitation pressure regime, is generally low in these high-perfused organs. Sonication strategies making use of shockwaves, millisecond boiling, and cavitation have been evaluated pre-clinically to enhance the energy uptake in the target area. However, the complex nature of these mechanisms has so far limited their application in clinical practice. The goal of this study was to investigate, under MR guidance and clinical conditions, whether a thermal ablation protocol using shockwaves and millisecond boiling can be used to enhance the energy uptake in the treatment area and ablate a confluent region in a highly perfused organ (porcine liver).
其他文献
Background,Motivation and Objective Vascular velocity measures by conventional duplex ultrasound can be unreliable since color Doppler is affected by aliasing and beam/flow angle.Several strategies we
会议
Background, Motivation and Objective In ultrasound transducers, the most popular fabrication method for 1-3 piezocomposites (i.e. aligned piezoelectric rods in a polymer matrix) is the ?Dice and Fill?
会议
Background,Motivation and Objective Recently,intravascular diagnosis like intravascular ultrasonography(IVUS)has been used clinically in medical field.The ultrasound probe should be rotated within the
会议
Background,Motivation and Objective Micromachined ultrasonic transducers(MUTs) are an emerging class of MEMS devices,which can be used in a wide variety of potential applications such as in gesture re
会议
Background,Motivation and Objective Recently,ultrasound applications with the assistance of high-intensity ultrasound pulse are used increasingly in medical systems.It is necessary to measure the dist
会议
Background,Motivation and Objective Ultrasonic imaging transducer is often required to compose a beam pattern of a low sidelobe level and a small beam width over a long focal region to achieve good im
会议
Background,Motivation and Objective Recently,1-3 piezocomposites are widely used in underwater acoustic transducers to overcome the limitation of conventional piezoceramics.However,the structure of th
会议
Background,Motivation and Objective In the ultrasonic transducer,a backing layer is generally made of composite material using metal powder and polymer to provide proper attenuation coefficient and ac
会议
Background,Motivation and Objective Brillouin scattering enables a nondestructive and noncontact technique to measure the hypersonic wave velocity in thin materials.However,weak thermal phonons result
会议
Background, Motivation and Objective Intracerebral hemorrhage (ICH) accounts for 10-15% of all stroke and is characterized by the bleeding and clotting in the brain caused by the rupture of blood vess