The investigation of reasonable selection of additional filtration in whole cerebral arteriography

来源 :中华放射学学术大会2016、中华医学会第23次全国放射学学术大会暨中华医学会第24次全国影像技术学术大会 | 被引量 : 0次 | 上传用户:ilclean
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective:To discuss how to properly select additional filtration in whole cerebral arteriography ,by comparsion of imaging quality and radiation dose. Method:1. PHILIPS Allura Xper FD20 arteriography machine was used ,select different additional filtration(0.1 mmCu+1mmAl; 0.4 mmCu+1mmAl;0.9 mmCu+1mmAl)in the mode of single exposion. Pictures were taken of rectangular wave testing card,one picture was acqusited. All imagings were analysed by two chief radiologists, one aid-radiology technic an one superior engineer. 2. 90 patients were selected continuously according to the same standard,and patients were randomly divided into three groups according to different additional filtration, group A (with additional filtration value of 0.1 mmCu+1mmAl ),group B (with additional filtration value of 0.4 mmCu+1mmAl ) and group C (with additional filtration value of 0.9 mmCu+1mmAl ).Routine whole brain arteriography were taken place ,the DAP、AK value、Kv、mAs and total number of frame were recorded while anterioposterior and lateral angiographic sequence were taken when the acquisition filed was 31 cm. Results:1.Rectangular wave test card display value showed 2.0Lp/mm, with 0.9mmCu+1mmAl and 0.1mmCu+1mmAl additional filtration; Rectangular wave test card display value showed 2.2Lp/mm, with 0.4mmCu+1mmAl.2.Image scores of group A,B and C were 3.79,3.5,2.85, group A and B effect of additional filtration on the image quality was not significant (P = 0.124), the image quality of group C with respect to the filtration of the first two decreased(P=0.000,P=0.001). 3.The additional filtration Cu thickness of group A,B and C increase 0.1mm to 0.4mm,0.9mm, when conventional anteroposterior the radiation dose of group B and C were reduced by approximately 24.7% and 59.7% with respect to group A; when conventional lateral the radiation dose of group B and C were reduced by approximately 59.5% and 73.2% with respect to group A. Conclusion:If0.4 mmCu+1mm were selected when PHIHPS Allura Xper FD20 arteriography machine were utilized in whole cerebral arteriography,not only the quality of imagings were ensured,but also the radiology doses of the patients were decreased.
其他文献
目的:探讨双下肢全长摄影技术在儿童骨关节疾病诊断中的应用价值. 方法:搜集我院2014年3月至2015年3月间所拍摄双下肢全长片共130份,进行回顾性总结分析. 结果:全部图像均完整显示双下肢,拼接完全、无伪影,对比度良好,完全满足诊断要求.130例样本中阳性改变114例(88%),阴性16例(12%),其中阳性改变前三位分别为:双下肢不等长27例(21%),膝外翻22例(17%),膝内翻14例(
目的:通过总结分析我院小趾缝匠趾患者手术的疗效,明确小趾缝匠趾的手术方法。方法:我院自2013年8月至2015年12月,手术治疗小趾缝匠趾病人22例,其中一型6例,二型7例,三型9例,合并轻度踇外翻3例,中度踇外翻2例,重度踇外翻2例。
会议
目的:通过比较图像质量和辐射剂量,探讨在全脑血管造影过程中如何合理的选择附加滤过. 方法:1.使用PHILIPS Allura Xper FD20血管造影机,选择不同附加滤过(0.1 mmCu+1mmAl;0.4 mmCu+1mmAl;0.9 mmCu+1mmAl),分别对矩形波测试卡摄影,采集单幅图像,由两名放射科主任医师、一名副主任技师及一名高级工程师共同分析获得的图像.2.按照统一的纳入标准
目的:浆细胞性乳腺炎的临床表现变化多样,早期诊断比较困难,本文探讨浆细胞性乳腺炎的MRI表现特点. 方法:回顾性分析经手术证实的42例浆细胞性乳腺炎.MRI检查包括DWI(b=1000s/mm2)、T1WI、脂肪抑制T2WI和动态增强扫描(VIBRANT),测量病变区的时间信号曲线(TIC)及ADC值,按照BI-RADS标准对病灶形态学进行分类评价. 结果:42例病人,年龄21~53岁,双侧发病的
目的:消除MRI中的图像处理相关伪影,改善MRI图像质量. 方法:总结我院最近一年的5632例MRI检查图像,扫描部位包括头颈部、脊髓、腹部、四肢,图像为TI、T2及PD加权像,扫描序列为SE、TSE、TSE-Restore、EPI、STIR、FLAIR、True FISP 等.体位为横轴位、冠状位、矢状位和斜位等.把其中有图像处理相关伪影的病例归纳分类,使用超导型磁共振成像仪(Magnetom
平片密度分辨率较低,发现肺部结节性病变的钙化较CT少见,尤其在肺癌中,CT由于具有较高的密度分辨率,是DR平片的数倍, 故比传统的DR平片检查能更多的发现肺内孤立性结节中的钙化,本文旨在研究、分析孤立性肺结节内的钙化灶多少、大小、形态、钙化程度(钙化灶密度的高低)及钙化灶在结节内的分布特征,综合分析、判断,为结节的良、恶性的鉴别诊断提供更有价值的信息。
Objective To investigate the relationship between DNA damage which was considered enhancing apoptosis and metabolites after radiotheraphy in U87 cells, and explore the possible molecular mechanism. Me
目的 磁共振全身类派特(PET)成像技术对恶性原发肿瘤及转移瘤的早期诊断临床应用价值。方法 借助于高场超导MRI的高分辨率和类PET 的高灵敏度,可以实现解剖结构显像和功能成像的互补。结果 56例中,类PET均清楚的显示恶性及转移瘤的早期情况及放化疗后的治疗情况。
目的 探讨PET/CT-MRI三模式在直肠癌局部分期中的诊断效能,比较PET/MRI融合与盆腔MRI、PET/CT在盆腔局部分期中的准确性. 方法 回顾性分析35例直肠癌患者术前PET/CT与盆腔MRI图像,并进行PET与MRI图像的融合,比较PET/MRI融合图像、盆腔MRI、PET/CT在直肠癌局部分期的诊断价值. 结果 35例直肠癌患者,病理及随访结果为T1期2例,T2期5例,T3期25例,
Purpose Irreversible electroporation(IRE) is an emerging ablative therapy which has now been widely recognized. It is a kind of local treatment by causing cell apoptosis. Compared with IRE ablation pe