Prediction of Temperature Rise in MV Switching Cabinet

来源 :第十三届国际机电装置会议(IS-EMD2013) | 被引量 : 0次 | 上传用户:tsinfang
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  A study has been undertaken of the temperature rise prediction for a medium voltage (MV) switching cabinet using a three dimensional finite element model.The features of key hardware components and factors affecting the prediction accuracy are discussed.A simplified model is employed to determine the heating effects due to contact resistance.Results show that the predicted temperature rise follows the patterns obtained from measurement and the major discrepancy caused by uncertainties in the determination of contact resistance inside the vacuum circuit breakers and movable contact fingers fastened by elastic rings.The roles of gas flow are analyzed.
其他文献
A break arc is generated in a DC48V and 9A resistive circuit for different contact opening speed.The speed is changed to 10ram/s, 20mm/s and 30mm/s.While the break arc is maintained, the morphology of
In a DC inductive load circuit (L=20mH) with a power supply voltage of DC14V, break operations of a load current in the range from about 0.8 to 4 A were conducted with a Ag contact pair and a AgSnO2 c
The reason for the small number of scientific studies on the dynamic welding process is the complex mechanism of dynamic welding.Dynamic welding model needs to include contact heating in the contact a
WC@SnO2 core-shell composite were fabricated by a modified sol-gel method, in which nano-scaled SnO2 particles were uniformly deposited on WC particles modified by PVP(Polyvinylpyrrolidone).And then t
Adjustability is an important function of the DC high speed Circuit Breaker magnetic release.Based on 3-D finite element method, the static characteristics of the magnetic release were obtained.The re
For break arcs occurring between Ag contacts in nitrogen atmosphere, calculations of the thermodynamic and transport properties (electrical conductivity, viscosity, and specific heat at constant press
For the direct measurement of very fast transient current (VFTC) due to switch operation in gas insulated switchgear (GIS), usually it will interfere the original operation or change the structure of
In communication systems, electrical connectors could easily be subjected to contaminants in the atmospheric environments.The presence of the contaminants could lead to connector failure which is one
A sliding contact is the process of transferring the electrical current between a stationary and moving object, which for DC motors involves a brush (stationary) and a commutator slip ring (moving).Th
The thermal phenomena of the spring contacts in high-voltage apparatus is studied.An experimental circuit is built to conduct AC and DC steady-state temperature rise test with the spring contacts as t