故障现象:M-2024打印机,开机面板显示正常,但打印字车不动作.故障分析与排除:打开机盖,进行外观检查,发现F1(2.5A)保险熔断.经查看电路图得知F1是打印机字车电机驱动电路与36V电源之间连接的保险管,目的是防止当电机过载使驱动电路短路而造成电源过载烧毁.换上一个新保险管通电立即烧毁,说明打印机字车驱动电路有短路故障.断电测量STA434A集成电路,该芯片是驱动管集成块,把4个三极管集成在一起,见图:
Fault phenomenon: M-2024 printer, the boot panel display is normal, but the print car does not move. Failure Analysis and Troubleshooting: Open the lid, the appearance of inspection and found F1 (2.5A) insurance fuse. F1 The word car motor drive circuit and 36V power supply connected between the fuse, the purpose is to prevent the motor overload to make the drive circuit is short circuit caused by power overload burned. Replace with a new fuse power immediately burned, indicating that the printer word car drive circuit has a short circuit fault Power off measurement STA434A integrated circuit, the chip is driving tube manifold, the four transistors integrated together, see Figure: