论文部分内容阅读
为研究泡沫微晶玻璃砖砌体的抗剪性能,依据《砌体基本力学性能试验方法标准》(GB/T 2542—2011)的方法步骤对四组抗剪试件进行了沿通缝截面的抗剪强度试验。通过对试验结果的分析,提出了泡沫微晶玻璃砖砌体抗剪强度的计算公式。由此计算公式计算的抗剪强度计算值与试验值吻合较好,泡沫微晶玻璃砖砌体的抗剪强度与蒸压灰砂砖砌体的抗剪强度相当,可在工程中推广应用。
In order to study the shear resistance of foam glass-ceramic brick masonry, according to the method steps of “Standard Test Method for Basic Mechanical Properties of Masonry” (GB / T 2542-2011) Shear strength test. Through the analysis of test results, the formula of shear strength of foam glass-ceramic brick masonry is proposed. The calculated shear strength calculated by this formula is in good agreement with the experimental value. The shear strength of the foam glass-ceramic brick masonry is equivalent to the shear strength of the autoclaved sand-lime brick masonry and can be widely applied in engineering.