在阴离子交换柱上,使用由NaClO_4和HCl组成的淋洗剂可以分离贵金属络合物[AuCl_4]-、[PdCl_4)~2-和(PtCl_6]~2-。这三种络合物可应用紫外光检测法检测,但对金来说,电流检测法有更好的灵敏度和选择性。采用预富集可使检测限达1ppb以下。该方法最适用于在HCI/HNO_3中溶解的样品,因为即使上述三种金属在样品中有不同价态,但经HCl/HNO_3处理后都成为上述的络合物形式。本方法能检测的其它金属还有Fe(Ⅲ)和pb(Ⅱ)。
The precious metal complexes [AuCl_4] -, [PdCl_4) ~ 2- and (PtCl_6] ~ 2- can be separated on an anion exchange column using an eluent consisting of NaClO_4 and HCl. These three complexes can be applied to UV However, for gold, the current detection method has better sensitivity and selectivity.Using preconcentration can limit the detection limit below 1ppb.This method is most suitable for the sample dissolved in HCI / HNO_3 because Even if the above three metals have different valences in the sample, they all become the complex forms above when treated with HCl / HNO3. Other metals detectable by this method are Fe (III) and Pb (II).