针对TC21钛合金电子束焊接接头残余应力过大问题,通过局部热处理工艺来改善其分布,分别采用X射线检测法和小孔法两种方法对电子束局部热处理后焊接残余应力的分布进行了测试研究。试验结果表明:两种测试方法测试结果趋势相同。焊后焊缝区残余应力较大,横向残余拉应力最高达到736 MPa,纵向残余压应力最高达到-468MPa,而经电子束局部热处理后,焊缝区横向及纵向残余应力峰值同焊接态相比都降低了70%~75%,而母材区域由于焊接态时残余应力较小,经过局部热处理扫描和未经过局部热处理扫描的区域残余应力几乎没有变化。
Aiming at the problem of excessive residual stress in electron beam welded joint of TC21 titanium alloy, the distribution of welding residual stress is improved by local heat treatment process. X-ray detection and pinhole method are respectively used to test the distribution of welding residual stress. the study. The test results show that the test results of the two test methods have the same tendency. After welding, the residual stress in the weld zone is larger, the maximum horizontal residual tensile stress reaches 736 MPa and the maximum longitudinal residual compressive stress reaches -468 MPa. After the electron beam local heat treatment, the horizontal and vertical residual stress peaks in the weld zone are compared with those in the welded state Are reduced by 70% -75%, while the residual stress in the base metal region is small due to the welding state, there is almost no change in the residual stress after local heat treatment scanning and without local heat treatment scanning.