Sommer曾提出用脉冲极谱测定镓和铟,灵敏度分别达到0.05ppm镓和0.1ppm铟。本文在前一工作的基础上,进一步研究了镓铟—茜素S络合物的吸附催化波。在0.26M氧化钾—0.08M乙酸钠(pH5)的底液中,当有1×10~(-4)M茜素S存在下,波高与浓度在0.01—0.4微克镓/毫升,0.004—0.4微克铟/毫升之间呈线性关系。峰电位分别为-1.13伏和-0.63伏(对S、C、E),因此可在同一底液中同时测定镓和铟。
Sommer proposed the use of pulsed polarography for the determination of gallium and indium with sensitivities of 0.05 ppm gallium and 0.1 ppm indium, respectively. Based on the previous work, this paper further studies the adsorption catalytic wave of gallium indium-alizarin S complex. In the presence of 1 x 10 ~ (-4) M Alizarin S in the bottom liquid of 0.26 M potassium oxide -0.08 M sodium acetate (pH 5), the wave height was in the range of 0.01-0.4 micrograms gallium / milliliter, 0.004-0.4 There is a linear relationship between micrograms of indium / ml. The peak potentials are -1.13 volts and -0.63 volts (vs. S, C, E), respectively, so that gallium and indium can be simultaneously measured in the same bath.