采用正交试验方法,对超滤膜处理滦河水系统运行参数进行优化,通过设计6因素3水平正交试验,对不同工况下膜系统ΔTMP进行分析,考察系统对浊度和有机物的去除效果。结果表明,不同运行参数对膜污染的影响由大至小排列为:膜通量>周期排空频率>过滤周期>反洗流量>反洗时间>气冲流量;膜系统参数的变化对膜出水水质的影响不显著。将正交试验与加权评分法相结合,综合考虑膜系统出水水质、稳定运行情况及产水率3方面判定因素,得出膜系统优化运行参数为:膜通量18 L/(m2.h),过滤周期90 min,5周期排空1次,反洗体积流量3.2 m3/h,反洗时间60 s,气冲体积流量4.8 m3/h。
The orthogonal test was used to optimize the operating parameters of the Luan River water system. The orthogonal design of 6 factors and 3 levels was used to analyze the ΔTMP of the membrane system under different operating conditions. The turbidity and organic removal efficiency . The results showed that the influence of different operating parameters on membrane fouling was arranged as follows: membrane flux> cycle emptying frequency> filter cycle> backwash flow> backwash time> gas flushing flow; membrane system parameters change The membrane effluent The impact of water quality is not significant. Combining the orthogonal test and the weighted scoring method, taking the factors of water quality, stable operation and water yield of membrane system into consideration, the optimal operating parameters of the membrane system are obtained as follows: membrane flux 18 L / (m2.h) Filtration cycle 90 min, 5 cycles emptying 1 time, backwash volume flow 3.2 m3 / h, backwash time 60 s, air volume flow 4.8 m3 / h.